![Unicor WE-1550-HT2 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/unicor/we-1550-ht2/we-1550-ht2_manual_3727104004.webp)
4
Unicor sa
11
Pump laser switch key
ON: On, OFF: Off.
Before the device is powered on, please confirm the key is in the
OFF position. After the device passes the self-test, turn the key to
the ON position according to the hint information.
12
Optical signal connectors
Be different with different configuration. Please refer to the print.
6. Operation Instructions of the Display Menu
▲
▼
key: The cursor can be moved left or right or up and down, and the selected module or menu is highlighted.
Enter
key: Press
Enter
to enter the next submenu or set the parameters in the submenu. Press
Enter
to confirm.
ESC
key: Exit or return to the previous menu.
Startup screen
Standby screen
In: xx.x out: xx.x
Unit: dBm
Optical input or output power
Unit
Parameter display submenu
Rev1.0 181016
XXXXXX
logo
XXXXXX
model
XXXXXX
startup countdown/lock status
Input Power: dBm
Input power, accurate to 0.1 dBm
Output Power: dBm
Output power, accurate to 0.1 dBm
PreEDFA Power: dBm
The first stage amplification. EDFA optical output power,
accurate to 0.1 dBm
Pump1 Bias: mA
Bias current of pump1, accurate to 1 mA
Pump1 Temper:
℃
Temperature of pump1, accurate to 0.1°C
Pump1 Tec: mA
Cooling current of pump1, accurate to 1 mA
Pump2 Bias: mA
Bias current of pump2, accurate to 1 mA
Pump2 Temper:
℃
Temperature of pump2, accurate to 0.1°C
+5V Read: V
+5V power supply voltage , accurate to 0.1 V
System Temper:
℃
Device temperature, accurate to 0.1 °C
SN:
Serial number
Ip Addr:
Ip address
Mask:
Subnet mask
Gateway:
Gateway
Mac:
Physical address
Trap Addr1:
trap1 address
Trap Addr2:
trap2 address
NTP Addr1
NTP server1 address
NTP Addr2
NTP server2 address
UTC offset
UTC offset
Software Version
Firmware version number