SW1: Sensibility and System Adjustment 

●  Clockwise rotating 

→ 

Increases the sensibility

 

!

 Set just to the necessary sensibility 

●  Anticlockwise rotating  → 

Reduces the sensibility

 

●  2s … 3s pushing 

→ 

Automatic setting of sensibility

 

Appropriated to detect the currently present target object. 
The LED 2 lights up after 2s pushing 

●  > 5s pushing 

→ Triggers 

system readjustment

 process. 

No object should stay over the electrodes. 

 

SW2: Configuration

 

Hysteresis

 

 

Memory-Function

 

 

 

SW2-1

 

 

SW2-2

 

 

 

ON 

20 % 

 

ON 

Active

!

   

 

OFF 

10 % 

 ♥ 

OFF 

De-active   ♥ 

♥ = 

 

Default Settings 

 

!

 

By  active  memory  function,  an  object  which  is  present  at  the  sensor  may  not  be  moved  or  removed  in 
power off time! 

 

Information Elements 

LED1

  is  active  by  measure-

ments. 
Its  activity  gives  an  idea 
about  the  level  of  the 
sensor detection signal. 

●  Slowly blinking (1/s) 

→ no or small sensor signal level. 

 

●  Moderate blinking (2/s)  → middle range sensor signal level. 

 

●  Fast blinking (4/s)  

→ high sensor signal level. 

 

For  safe  detection  of  objects,  it  should  be  selected  a  greater  range 
(SW2-3, SW2-4)! 

 

●  Permanently on (1)  → the sensor signal level is very high and is near

or is exceeding the measurement range limits. 

 

 

For  safe  detection  of  objects,  it  should  be  selected  a  greater  range 
(SW2-3, SW2-4)! 

LED2

  informs  about  the  push 

duration  of  the  switch 
SW1. 

●  0 s ... 2 s  →  LED2 off 

 

●  2 s … 5s  →  LED2 on 

 

●  > 5 s 

→  LED2 off 

LED3

  Lights when the sensor signal exceeds the measurement range limits. 

LED4

 

– 

always ON 

if the system falls in error conditions. The evaluation unit stops working. To 
restart it is necessary to perform a readjustment procedure. 

 

– 

slow blinking (1/s)  while in adjustment [comparison] procedure. 

LED5

  lights when relay is on (busy sensor electrodes). 

LED6

  is the operation indicator. It lights when the evaluation unit is on. 

 

Function Explanation (Turning OFF without memorization)

 

Case the detector device is switched OFF while the memory function is inactive and an object is left in the 
detection area, the device “ignores” this condition. In this case, when the device is switched ON again, it will 
proceed with a new adjustment considering free detection area and the relay will stay OFF. 
To be sure about this procedure, one can move his hand to the detection area to see the relay turning ON. 
After removing the object and subsequently the hand from the detection area, the relay turns OFF again and 
around 2s later the new conditions will be detected by the device as empty area. 
The sensitivity setting is always saved, even in the case when the device is switched off. On the next switch-
ing ON, it will be recovered the same sensitivity from the last operation time. 