6.

 

Transportation and Storage 

The battery charger shall be stored in heated space at air temperature of +5 º

С

 to +35 º

С

 

(maximum values of -60 º

С

 to +70 º

С

), at relative humidity of air not exceeding 95 % at 

temperature of +25 °C and content of dust, oil, moisture and aggressive admixtures in the air not 
exceeding the norms envisaged by GOST 12.1.005-88 for the working zone of production areas. 

The device shall be transported in transport container of the manufacturer in closed 

transport. 

Means of transport: 

 

automobile and railway closed transport (covered wagons, universal containers) 

 

by air (in pressurized and heated bays of airplane) 

 

by sea (in dry service spaces). 

The device shall be transported in accordance with the transport regulations in force for 

the particular transport. 

During handling operations and transportations strictly observe the requirements of 

handling marks on boxes and do not allow bumps and impacts which can affect preservation and 
serviceability of the device. 

Packed devices shall be reliably secured in vehicles. 

After storage in stores or transportation at temperature below +10 º

С

 the devices shall 

be unpacked only in heated spaces after keeping them unpacked in under normal climatic 
conditions for12 hours. 

 

 

Содержание PS-303

Страница 1: ...Unicont SPb Ltd Power supply unit PS 303 Technical Documentation 303 4 04022011 St Petersburg 2011...

Страница 2: ...ents 1 GENERAL INFORMATION 3 2 DELIVERY SET 3 3 TECHNICAL DATA 3 4 DESCRIPTION AND FUNCTIONALITY OF THE PS 303 PSU 4 5 INSTALLATION AND CONNECTION 5 6 TRANSPORTATION AND STORAGE 11 7 WARRANTY 12 8 DAT...

Страница 3: ...wn in the electrical data table Table 1 Input voltage Load transfer 110 220 50 Hz 24 V 12 V depending on the model see the electrical data table Automatic load transfer from input 1 to input 2 in case...

Страница 4: ...inputs i e input 1 for the main network and input 2 for the backup one two terminals for the loads and light emitting diodes indicating power supply from the main network or from the backup one see F...

Страница 5: ...irements of this Operating Manual 110 or 220 V AC The PSU input power factory setting is 220 V 50 60 Hz If the main power supply of the PSU is going be 110 V 50 60 Hz 110 V should be selected on the p...

Страница 6: ...Unicont SPb Ltd Technical Documentation PS 303 Page 6 Figure 2 PSU installation drawing...

Страница 7: ...cal Documentation PS 303 Page 7 Figure 3 Voltage switch Load 1 1 24 VDC 24 VDC OUTPUT PS 303 Load 2 2 T GND T GROUND INPUT 220 V AC Input 1 24 VDC 24 V Batt Input 2 N 220 VDC L Figure 4 PS 303 connect...

Страница 8: ...umentation PS 303 Page 8 Figure 5 PS 303 connection diagram 220 12 12 Load 1 1 24 VDC 24 VDC OUTPUT PS 303 Load 2 2 T GND T GROUND INPUT 24 V DC Input 1 24 VDC 19 36 Batt Input 2 24 VDC Figure 6 PS 30...

Страница 9: ...tation PS 303 Page 9 Figure 7 PS 303 connection diagram 24 12 12 Load 1 1 12 VDC 12 VDC OUTPUT PS 303 Load 2 2 T GND T GROUND INPUT 220 V AC Input 1 24 VDC 19 36 Batt Input 2 N 220 VAC L Figure 8 PS 3...

Страница 10: ...Unicont SPb Ltd Technical Documentation PS 303 Page 10 Figure 9 PS 303 connection diagram 3 12 12 12 Figure 10 PS 303 connection diagram 3 24 24 12...

Страница 11: ...ransport automobile and railway closed transport covered wagons universal containers by air in pressurized and heated bays of airplane by sea in dry service spaces The device shall be transported in a...

Страница 12: ...ondition or has a damaged body and other causes beyond the manufacturer s control 4 If self made electrical devices were used 5 If there was an attempt to repair the unit by a person who is not an aut...

Страница 13: ...r was manufactured and accepted in accordance with the regulatory requirements of the state standards and applicable technical documentation and is suitable for operation Quality control representativ...

Отзывы: