10
Figure 14. Location of connectors and control cable in LCD display
Figure 15. Switching card
4.
Connect the other end of the power cable connected to J4 connector of the switching
card to the power supply connector of LCD display (Figure 14).
5.
Connect cables disconnected from the sweep unit (marked previously) to the
corresponding connectors of the display and switching card:
–
connect RGB cable (removed from D-sub connector) to the display VGA
connector (Figure 14);
–
connect power supply cable (removed from J576 connector) to J3 connector (IN
140 (V) of the switching card (Figure 15);
–
connect dimmer control cable (removed from J579 connector to J2 connector
(dimmer) of the switching card (Figure 15).
6.
On termination of device connection, apply power to it and turn on the installation.
–
Adjust radar brightness control to maximum.
–
Check the image quality reproduced by the display.
–
In case of incorrect image, enter LCD display menu (see section 6) and use Auto
adjust menu function (automatic control), then go to menu item adjusting image
vertical and horizontal displacement, and adjust the position of the image
displayed.
7.
Using mounting bolts, fix the protective frame with display in radar bracket (see
Figure 3).