4.
MOUNTING AND CONNECTION
Device casing provides for it to be mounted on the desktop and on the plate.
If plate mounting is chosen, refer to the dimensional drawing (Figure 1) to prepare the
location where the display is to be mounted to the control panel plate with fixing holes. If desktop
mounting is chosen, attach the brackets to the display casing, prepare the location and tighten M5
screws to fix the display to the brackets.
Mounting being completed, lay connecting cables from external devices and connect it to the
matching display connectors. Tighten the fixing screws to avoid their inadvertent disengagement.
After mounting and connection are completed, power the device up and ensure that the
graphical data are properly output on the screen.
It is possible to connect several video signal sources (1 x VGA, 1 x DVI, 2 x AV and 1 x S-
Video).
Power Connector
Power
Pin 1
Pin 2
24 VDC
+18...36 VDC
0 VDC
220 VAC
L
N