19
GENERAL INTRODUCTION
LAN 1
Intel
®
I219LM GigE LAN supports iAMT 11.0
LAN 2
Intel
®
I210 GigE LAN
LAN 3
Intel
®
I210 GigE LAN
LAN 4
Intel
®
I210 GigE LAN
Power
Input Voltage
6V to 36V, DC-in
Power Interface
• 3-pin Terminal Block : V+, V-, Frame Ground
• Mini-DIN 4-pin
Ignition Control
16 Mode (Internal)
Remote Switch
3-pin Terminal Block : On, Off, IGN
Surge Protection
Up to 80V/1ms Transient Power
Others
TPM
Optional Infineon SLB9665 supports TPM 2.0, LPC
interface
Watchdog Timer
Reset : 1 to 255 sec./min. per step
Smart Management
Wake on LAN, PXE supported
HW Monitor
Monitoring temperature, voltages. Auto throttling control
when CPU overheats.
Software Support
OS
Windows 10, Windows 8.1, Windows 7, Linux
Mechanical
Dimensions (WxDxH)
260mm x 175mm x 79mm (10.24" x 6.89" x 3.11")
Weight
3.8 kg (8.38 lb)
Mounting
• Wallmount by mounting bracket
• DIN Rail Mount (Optional)
• 2U Rackmount (Optional)
Environment
Operating Temperature • 35W TDP CPU (i7-6700TE, i5-6500TE, i3-6100TE) :
-40°C to 75°C (-40°F to 167°F)
• 65W TDP CPU (i7-6700/ i5-6500/ i3-6100) :
-40°C to 55°C (-40°F to 131°F)
Storage Temperature
-40°C to 85°C (-40°F to 185°F)
Humidity
5% to 95% Humidity, non-condensing
Relative Humidity
95% at 70°C
Shock
• IEC 60068-2-27
• SSD : 50G @ Wallmount, Half-sine, 11ms
Vibration
• IEC 60068-2-64
• SSD : 5Grms, 5Hz to 500Hz, 3 Axis
EMC
CE, FCC, EN50155, EN50121-3-2
Содержание Echo236F
Страница 2: ...ii Version Date Page Description Remark 1 0 11 25 2016 All Official Release Record of Revision ...
Страница 67: ...60 HARDWARE INSTALLATION Echo 236F User Manual Step 4 Finish Step 3 Remove bottom four F 6 32 screws ...
Страница 71: ...64 HARDWARE INSTALLATION Echo 236F User Manual Step 4 Open CPU slot Be careful CPU pin Step 3 CPU slot ...
Страница 72: ...65 HARDWARE INSTALLATION Step 6 Finish Step 5 Installing CPU on the slot Step 7 Close CPU slot and finish ...
Страница 84: ...77 HARDWARE INSTALLATION 3 9 Installing M2DOM Step 2 M2DOM module Step 1 M2DOM slot ...
Страница 87: ...80 HARDWARE INSTALLATION Echo 236F User Manual Step 2 Fasten 4pcs KHS 6 32 screws then finish ...
Страница 113: ...106 Echo236 User Manual Spendix A On Device Manager Embedded IO Access will be added Please press any key to restart ...