24 Port 10/100Base-TX Switch

with Dual Port 100/1000 Module Slot

SmartGST-2402

U

SER’S 

M

ANUAL

GEP-31124T-1

s e r i e s

All manuals and user guides at all-guides.com

all-guides.com

Содержание GST Series

Страница 1: ...NICOM 2004 UNICOM and A Network Systems Solution are trademarks of UNICOM Electric Inc All rights reserved Specifications subject to change without notice Rev 09 04 24 Port 10 100Base TX Switch with D...

Страница 2: ...ed Installation 9 3 NETWORK APPLICATION 11 4 CONSOLE MANAGEMENT 14 Login in the Console Interface 14 Main Menu 15 Port Status 17 Port Configuration 17 Trunk Configuration 18 Trunk Status 19 QoS 20 Pri...

Страница 3: ...APPENDIX 29 Console Port Pin Assignments 29 Cables 30 100BASE TX 10BASE T Pin Assignments 30 All manuals and user guides at all guides com...

Страница 4: ...witch to auto learn and store source address in an 8K entry MAC address table MDI Medium Dependent Interface Port is also called an uplink port The MDI port does not cross the transmission and recepti...

Страница 5: ...ol Pause frame for full duplex mode Backpressure for half duplex mode Store and forwarding switching architecture for abnormal packet filtering High switch fabric up to 8 8Gbps 8K entry MAC address ta...

Страница 6: ...Port based priority 2 TCP IP TOS DiffServ DS priority field 3 802 1p priority tag Class of Service System provides two queues for High and Low priority Support priority weighted ration H L 1 0 always...

Страница 7: ...kage Contents Compare the contents of your SmartGST 2402 package with the standard checklist above If any item is missing or damaged please contact your local dealer for service Ethernet Switching Tec...

Страница 8: ...peed and duplex of each port based on the capability of both devices Flow control allows transmission from a 100Mbps node to a 10Mbps node without loss of data Auto negotiation and flow control may ne...

Страница 9: ...four 10 100Base TX RJ 45 ports Auto MDI MDIX and one expansion slot The LED Indicators are also located on the front panel of the Switch Figure 2 1 The Front panel of SmartGST 2402 RJ 45 Ports Auto M...

Страница 10: ...een Power On Power Off Power is not connected Green The port is connecting with the device Blinks The port is receiving or transmitting data LNK ACT Off No device attached Orange The port is operating...

Страница 11: ...nough clearance around the Switch to allow attachment of cables power cord and allow air circulation Attaching Rubber Feet A Make sure mounting surface on the bottom of the Switch is grease and dust f...

Страница 12: ...with the holes on one side of the switch and secure it with the smaller bracket screws Then attach the remaining bracket to the other side of the Switch Figure 2 4 Attach mounting brackets with screws...

Страница 13: ...for enclosed rack installations Power On Connect the power cord to the power socket on the rear panel of the Switch The other side of power cord connects to the power outlet The internal power supply...

Страница 14: ...sed to filter and forward all traffic based on the destination address By using any port as an uplink port the Switch can connect with another switch or hub and interconnect other small switched workg...

Страница 15: ...s are constantly broadcast In the illustration below two Ethernet switches with PCs a print server and a local server are all connected to the Switch All the devices in this network can communicate wi...

Страница 16: ...that enables a connection to a PC or terminal for monitoring and configuring the Switch Use the supplied RS 232 cable to connect a terminal or PC to the Console port The Console configuration out of...

Страница 17: ...e following default characteristics of the console port Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None Figure 4 1 The settings of communication parameters After finishing the...

Страница 18: ...and Network Loop fault port detected information 5 QoS configure QoS function and setup the ports priority 6 Priority Tag Insert Remove configure the ports tagging control 7 System enable VLAN functi...

Страница 19: ...left and right Enter Edit finish or OK in function screen Space Toggle selected item to next configure or change the value 0 to exit the current action mode E to edit the parameter or configuration Sp...

Страница 20: ...is connecting with the device and work normally the link status is UP Opposite is Down Flow Control display the flow control status is enable or disable Auto Negotiation display the auto negotiation s...

Страница 21: ...iver bandwidth Note You must to enable the Flow control for Rx Tx bandwidth to work Trunk Configuration It supports 8 trunk groups as follows Trunk1 Port 1 2 Trunk 2 Port 3 4 Trunk 3 Port 5 6 7 8 Trun...

Страница 22: ...interface Trunk Status This window displays the trunk link warning information When the trunking group has detected an error the information will be displayed in this section Trunk Status interface Al...

Страница 23: ...e is 16 1 1 0 the switch will process all high priority packets 4 1 the switch will process 4 high priority packet first the process 1 low priority packet 8 1 the switch will process 8 high priority p...

Страница 24: ...passes through the high priority port Insert Tag All frame Inserts the packet s tag when the packet passes through this port Priority Tag Insert Remove interface System You can enable VLAN function an...

Страница 25: ...ber Setup Configuring Port Base VLAN group Add VLAN Group 1 Enter E to switch to Edit Mode 2 Press A to start adding a VLAN group 3 Use L and J to move to the port that you want to add into a VLAN gro...

Страница 26: ...Entry No 3 Press Enter The system will ask you to confirm the deletion Enter y to confirm the deletion 4 Press Enter the VLAN group will be deleted 5 Press U to update the VLAN information to system...

Страница 27: ...ons changes Without saving the configuration the new setting will not take effect If you turn off the device without saving the configurations all changes will be permanently lost All manuals and user...

Страница 28: ...er cable mode and fiber module should be match Faulty or loose cables Look for loose or obviously faulty connections If they appear to be OK make sure the connections are snug If that does not correct...

Страница 29: ...ave a problem with power outlet or power cord However if the Switch powers off after running for a while check for loose power connections power losses or surges at power outlet IF you still cannot re...

Страница 30: ...cators System power 10 100Base TX Link Activity Full Duplex Collision 100FX Link Activity Full Duplex Gigabit SX LX Link Activity 1000Base T 100 1000 Link Activity Full Duplex Collision Connector 10 1...

Страница 31: ...00 240VAC 50 60Hz Power Consumption 20Watts Maximum Dimensions 440mm x 161mm x 44mm L x W x H EMI Safety FCC Class A CE UL cUL CE EN60950 All manuals and user guides at all guides com a l l g u i d e...

Страница 32: ...C running a terminal emulation program The pin assignments used to connect to the serial port are provided in the following tables Figure 6 1 DB 9 Console Port Pin Numbers DB 9 Port Pin Assignments EI...

Страница 33: ...e PCs servers switches routers or hubs Please refer to the following table for cable specifications Cable Types and Specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100 ohm UTP 100 m...

Страница 34: ...ugh cables pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pi...