background image

Bulletin 30-122.2014.04.006 

Copyright © 2014 Unico, Inc. 

(SAC xx.xxxx.xxx.xx) 

 

Open the front panel of the unit. Remove the cover 
plate screw to reach the terminal strip. 

Insert the wires from the back, secure them with a conduit 
connector mounted in the knockout, and connect them to 
the power terminals. 

 

There are two conduit connection holes on the rear of the 
unit. Use the ¾ inch (22 mm) hole for the power lines and 
use the ½ inch (12.7 mm) hole for the communication 
cable. 

 

RIGHT REAR TUBING

 

 

Insert refrigerant tubes and drain hose of the unit into the 
hole in the wall then hang the unit on the panel previously 
mounted on the wall. 

 

Connect the line set to the refrigerant tubing on the outside 
of  the  wall  (refer  to  outdoor  unit  installation  manual  for 
instructions for making flare connections). 

LEFT REAR TUBING

 

 

Insert the tubes connecting the units from the outside, then 
bend them right and remove the interior removable part of 
the  frame.  Hang  the  unit  and  extend  the  support  on  the 
back of indoor unit to make the connection easier. 

 

Make a flare on the end of the line set and connect the 
line set (refer to the outdoor unit installation manual for 
instructions for making flare connections). 

 

Push lightly to fix the unit to the rear panel. 

 

 

 

P

Q

R

S

Содержание IS12MPA iSeries

Страница 1: ...Room temperature 91 F 27 C D B Cooling Minimum conditions Outdoor temperature 5 F 15 C D B Room temperature 50 F 10 C D B 17 F 6 C W B Heating Minimum conditions Outdoor temperature 25 F 32 C D B Roo...

Страница 2: ...connection points and a possible fire hazard Do not allow wiring to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and...

Страница 3: ...areas where electrical wiring or conduits are located DO Choose places as cool as possible and well ventilated use lug bolts or equal to bolt down the unit reducing vibration and noise Deoxidized anne...

Страница 4: ...anel as a template Check the horizontal position with the level Mark the holes to be made Drill a 2 5 inch 65 mm diameter hole Insert a 2 inch PVC pipe and secure in place Prepare wall for attachment...

Страница 5: ...h lightly on the shown marks arrows Tubing connections on right or left side Cut a corner of the frame The refrigerant tubes and drain hose are on the right side of the unit The drain tray is supplied...

Страница 6: ...se of the unit into the hole in the wall then hang the unit on the panel previously mounted on the wall Connect the line set to the refrigerant tubing on the outside of the wall refer to outdoor unit...

Страница 7: ...unit malfunction A fire hazard may also exist Therefore be sure all wiring is tightly connected Install the condensate drain to the outside with a positive slope The condensate can then be carried awa...

Страница 8: ...rotection MOP IS18G50 1 phase 60 Hz 208 230 V 10 0 13 20 IS24G65 12 5 16 25 IS30G80 16 0 20 35 IS36G110 22 0 28 50 Indoor units MODEL Power Supply Full Load Current Minimum Circuit Ampacity MCA Maximu...

Страница 9: ...rews and hang the remote control unit To reset the indoor unit to default factory setting set the remote control as follows Filter ON Night Mode High Power Mode OFF Operation mode AUTO Flap AUTO Set p...

Страница 10: ...NG Disconnect the power 1 Disconnect the power of indoor unit 2 Remove the batteries from the remote control unit 3 Set the micro switches see table The switches are located in the battery compartment...

Страница 11: ...circuit board inside the control box Disconnect the power of indoor unit Set the micro switches see table below Switch on the indoor unit At this point the system will operate with the new address OU...

Страница 12: ...et the remote controller of unit 1 as follows units 2 3 and 4 must be OFF Mode cooling Filter ON Set point 90 F 32 C 3 Press FAN IFEEL button for at least 5 seconds pointing the remote control unit di...

Страница 13: ...lso be used to reach 77 but this will not change the display from Celsius to Fahrenheit or vice versa 4 To finish the switch press and hold the Filter Shift button for 6 seconds This will cause the re...

Отзывы: