Before installation, it is recommended to carry out a 

technical assessment and obtain an opinion from an 

authorized chimney cleaning company. 

To connect the insert to the smoke duct, use a pipe made of 

certified heat-resistant sheet with a diameter equal or larger 

than the diameter of the outlet pipe of the fireplace. 

To ensure proper draft and to prevent local sooting, it is 
recommended to use pipe elbows with a slope of max. 45°. 
The total height of the chimney must be min. 4m. 

If the pressure in the chimney is insufficient (lower than the 

one in the table for the given model of the insert), a draft 

boosting device should be installed on top of the chimney. 

 

 

 

 

 

 

 

4.6.  Connecting  the  Nemo  insert  to  the  central  heating 

system 

 Fireplace inserts Unico with a water jacket can be used in 

gravity or pump heating open systems as an independent 

or supporting heating source. The installation should be 

secured in accordance with the requirements of PN-B 

02413:1991. 

a) 

 Open system

 

• 

 The maximum pressure of the installation should be 1.9 
bar. 

• 

An open expansion vessel should be connected with a 

pipe of 

 min. 28 mm. 

• 

The expansion vessel must be located above the 

highest point of the installation, the overflow hole should 

be 0 1". 

• 

If the fireplace insert is to be installed with another 

boiler operating in a closed system, a separating plate 

heat exchanger should be used. 

• 

 Regardless of the type of installation, air vents should 

be used in those places where there might appear air traps. 

• 

 The central heating installation should be made in such 

a way as to always maintain the temperature of water 

return to the fireplace above the dew point, i.e. approx. 
50°C (e.g. by installing a thermostatic mixing valve 
ensuring an appropriate return temperature). This is a 

requirement for the warranty to be recognized in the 

event of the insert malfunction. This prevents the insert 

from humidity resulting from condensation, and hence 

from corrosion. 

 

 

Dragon inserts are equipped with the so-called system 

thermal protection of 
the floor 

air inlet  
50cm3 / 1kW of generated power 

chimney connection 

1.4x air inlet surface 

thermal insulation 

decompression chamber 
(in the case of a wooden 
ceiling, ventilate) 

Содержание Dragon Series

Страница 1: ...USER MANUAL...

Страница 2: ...d energetic parameters of the insert In order to make the most of the technical parameters of the Unico insert as well as to ensure perfect safety during its use we kindly ask you to read carefully an...

Страница 3: ...ual 5 4 1 Fire protection 5 4 2 Ventilation 6 4 3 Combustion air supply 6 4 4 Heating air circulation 6 4 5 Chimney 6 4 6 Connecting the Nemo insert to the central heating system 7 4 7 Notes on the fi...

Страница 4: ...tional and local provisions should also be complied with 3 Safety recommendations Unico fireplace insert is a device that is completely safe and provides satisfaction and joy of use when installed and...

Страница 5: ...eplace insert must be a self supporting structure without any direct connection to the insert It should provide easy access to the insert and its connections for servicing and inspection purposes The...

Страница 6: ...bearings and other elements of the insert as well as the fireplace housing It is recommended to protect the air intake from dust and sand from the outside which may damage the air intake control mecha...

Страница 7: ...pressure of the installation should be 1 9 bar An open expansion vessel should be connected with a pipe of min 28 mm The expansion vessel must be located above the highest point of the installation t...

Страница 8: ...Notes on the first start up The first start up of the insert must be made before installing the fireplace After the first usage of the insert a check should be made whether the central heating instal...

Страница 9: ...e recommended method for Unico inserts making burning cleaner with less smoke emission which in turn makes the whole process more ecological and efficient d Open the combustion air inlets completely e...

Страница 10: ...gram below open c l o s e d 5 5 Cleaning the insert Systematic cleaning and maintenance of the fireplace insert is required for its safe and proper operation and also affects its aesthetic appearance...

Страница 11: ...e fireplace insert with the door open b Take proper care if there are children in the room where the fireplace is used The glass temperature can often exceed 300 C which when handled carelessly can ca...

Страница 12: ......

Отзывы: