28
Failure that could NOT cause stop of the boiler:
- Error code is displayed, the boiler is in CH demand,
Icon Reset (note that was detected a fault even if the
fault was temporary. Is therefore necessary always
push reset to clear the display’ ‘‘error’’.
Failure that causes the stop of the boiler:
- The error code is displayed, the boiler is in lock. After
resolving the fault press Reset to restart the boiler.
CODE (HCM)
DESCRIPTION detected on BMM
SOLUTION
ALARM_
0
Regular operation
ALARM_1
Overheat thermostat
ALARM_2
Low gas pressure
ALARM_3
Overheat thermostat
ALARM_
4
Ignition failure
Check the gas supply or that the ignition/de
-
tection electrode is working properly
ALARM_5
Flame lost
Check the detection electrode
ALARM_6
Overheating
Check pump operation and if needed
clean the heat exchanger
ALARM_7
Aux temperature sensor
ALARM_8
Low water pression
ALARM_9
Outer temperature sensor
ALARM_10
Internal failure
ALARM_11
Unexpected flame
ALARM_12
CH flow sensor
Check the efficiency of the sensor (see table
Res/Temp) or its connections.
ALARM_13
DHW Temperature sensor
ALARM_14
CH return sensor
Check the wiring, if needed, replace the sensor
ALARM_15
Differential temperature
Check pump operation and its speed - remove
any obstructions in the heating system
ALARM_16
Frozen
Disconnect power, close the gas valve, de
-
frost the heat exchanger carefully.
ALARM_17
Global frozen
ALARM_18
Global differential temperature
ALARM_19
Global overheating
ALARM_20
Gas valve leaking
Check the wiring and for any leaks from the
gas valve, replace the Gas valve if needed
WARNING!
Function reserved exclusively to
authorized service centers.
2.10 - Error Codes