8
Technical characteristics and dimensions
2.3 - GENERAL CHARACTERISTICS
Total water content
PU insulation hard type
Soft insulation
External diametre with 50 mm hard PU insulation
External diameter with soft insulation
Lower heat exchanger
Absorbed output
Water flow rate necessary for the coil
DHW product with prim.@ 80°/60° and sec.@ 10°/45° (DIN 4708)
Pressure losses
Flange
Dry weight
Max Working Pressure on DHW side
Max Working Pressure on Heating side
Max Working Temperature on DHW side
l
mm
mm
mm
mm
m²
kW
m
3
/h
l/h
mbar
Ø mm
kg
bar
bar
°C
150
168
50
-
600
-
1,0
24
1,0
600
12
180/120
70
10
6
95
SANICAL SC
200
212
50
-
600
-
1,5
36
1,6
900
40
180/120
90
10
6
95
300
291
50
-
600
-
1,8
44
1,9
1100
70
180/120
115
10
6
95
400
423
50
-
750
-
1,9
46
2,0
1109
80
180/120
140
10
6
95
600
589
50
-
750
-
2,5
63
2,7
1500
192
180/120
190
10
6
95
500
500
50
-
750
-
2,2
55
2,4
1400
131
180/120
155
10
6
95
Total water content
PU insulation hard type
Soft insulation
External diametre with 50 mm hard PU insulation
External diameter with soft insulation
Lower heat exchanger
Absorbed output
Water flow rate necessary for the coil
DHW product with prim.@ 80°/60° and sec.@ 10°/45° (DIN 4708)
Pressure losses
Flange
Dry weight
Max Working Pressure on DHW side
Max Working Pressure on Heating side
Max Working Temperature on DHW side
l
mm
mm
mm
mm
m²
kW
m
3
/h
l/h
mbar
Ø mm
kg
bar
bar
°C
800
765
-
100
-
990
2,7
68
2,9
1700
240
180/120
215
10
6
95
SANICAL SC
1000
888
-
100
-
990
3,5
88
3,8
2100
518
180/120
245
10
6
95