Unical SANICAL SC 1000 Скачать руководство пользователя страница 18

18

Instructions for the installer

In absence of the date of putting into service, the guarantee is 
considered from the date of manufacture of the storage tank.

B - The guarantee is valid provided that the certificate is compiled in 
all of its parts.

C - The guarantee covers all the components of the appliance and 
gives the right, to the user, to get, free of charge, any part that 
presents manufacturing defects only if the a.m. parts are returned, 
free of charge, to Unical, with attached copy of the records of the 
maintenance made on the storage tank by an authorised 
technician. 
The replaced or the repared parts will be returned to the owner 
with the charge of the freight and packing (if any) costs. 
The intervention of the service personnel will be effected against 
the reimbursement of the fixed call right. 

D - The guarantee doesn't cover the appliances that had been 
wrongly installed or have undergone a wrong maintenance or have 
been tampered, or for causes non dependent from the manufacturer. 

A -     This guarantee has effect from the date of putting into service.

GENERAL CONDITIONS OF CONVENTIONAL GUARANTEE

F - For any dispute exclusively the court of Mantua will be competent. 

E - The guarantee is considered elapsed in case of:

WARNINGS: In this type of appliances it is necessary to perform 
with regularity a cleaning that assures a minimum consumption 
and a maximum comfort. We suggest you to undersign an annual 
service contract with the nearest Unical after sales service or 
installer, that will validate this guarantee. 

1) lack of replacement, also following a non verification, of the 
magnesium anode, because every storage tank is protected 
by the anode against possible galvanic currents. 
The date of the anode replacement must be written on the 
following certifcat and countersigned by the technician himself. 

2) Use of the appliance for uses different from those to which it 
is destined or with different methods from those described in 
this instruction manual. 

3) Lack of service according to the instructions indicated in 
this manual. 

4) Installation not in conformity with the instructions given in 
this manual.

Содержание SANICAL SC 1000

Страница 1: ...INSTALLATION USE AND SERVICING INSTRUCTIONS GB 00332907 2st edition 09 2008 SANICAL SC 150 200 300 400 500 600 800 1000...

Страница 2: ...3 5 Preliminary checks 10 3 6 Hydraulic connections 11 3 7 Basi installation scheme 12 3 8 Filling of the installation 12 3 9 Diagrams of the pressure losses 13 3 10 First utilisation 16 4 INFORMATIO...

Страница 3: ...cing device is recommended The choice of this device has to be made taking into consideration the characteristics of the water In order to improve the resistance to lime scale it is recommended to adj...

Страница 4: ...ised service technicians UNICAL recommends drawing up a service contract Bad or irregular servicing could compromise the safe operation of the appliance and could cause injury to persons animals or da...

Страница 5: ...he com ponents for heating systems for civil use domestic hot water production for sanitary use and maintenance A wrong installation or a bad maintenance can cause dama ges to people animals or things...

Страница 6: ...0 storage tank with 200 liters capacity SC 300 storage tank with 300 liters capacity SC 400 storage tank with 400 liters capacity SC 500 storage tank with 500 liters capacity SC 600 storage tank with...

Страница 7: ...290 290 345 345 345 345 350 G 385 375 375 440 440 440 560 555 H 620 750 890 795 880 985 1035 1235 I 1165 960 1170 1340 1145 1395 L 1275 1535 M 765 975 1390 1185 1415 1685 1435 1700 N 990 1215 1615 14...

Страница 8: ...40 180 120 90 10 6 95 300 291 50 600 1 8 44 1 9 1100 70 180 120 115 10 6 95 400 423 50 750 1 9 46 2 0 1109 80 180 120 140 10 6 95 600 589 50 750 2 5 63 2 7 1500 192 180 120 190 10 6 95 500 500 50 750...

Страница 9: ...rity that could jeopardize the good operation of the storage tank ATTENTION THE APPLIANCE HAS TO BE INSTALLED BY A QUALIFIED TECHNICIAN WHO UNDER HIS OWN RESPONSIBILITY GUARANTEES THE RESPECT OF THE N...

Страница 10: ...tial source of danger for their safety 3 5 PRELIMINARY CHECKS ATTENTION Before connecting the storage tank to the heating system proceed with an accurate cleaning of the pipelines with a convenient pr...

Страница 11: ...1 Rp 1 RC Return to the boiler Rp 1 Rp 1 Ric D H W recirculation Rp Rp 1 F Cold water inlet Rp 1 R 1 1 Magnesium anode Rp 1 Rp 1 2 Thermometer Temp sensor Rp Rp 3 Electrical heater Rp 1 Rp 1 4 Inspec...

Страница 12: ...ation Boiler MC RC Cold water supply Pressure reducing valve Gate valve Gate valve Safety valve set at 6 bar Domestic hot water expansion vessel Attention The hydraulic scheme shown in this manual is...

Страница 13: ...SURE LOSSES SANICAL SC 150 200 300 SANICAL 150 0 50 100 150 200 250 300 0 1 2 3 4 5 m 3 h mbar inf SANICAL 200 0 50 100 150 200 250 300 350 400 450 0 1 2 3 4 5 m 3 h mbar inf SANICAL 300 0 50 100 150...

Страница 14: ...ICAL 400 0 50 100 150 200 250 300 350 400 450 500 550 0 1 2 3 4 5 m3 h mbar inf SANICAL 500 0 50 100 150 200 250 300 350 400 450 500 550 600 0 1 2 3 4 5 m 3 h mbar inf SANICAL 600 0 50 100 150 200 250...

Страница 15: ...ler SANICAL SC 800 1000 SANICAL 800 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 0 1 2 3 4 5 m3 h mbar inf SANICAL 1000 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850...

Страница 16: ...o determine the real state of an ap pliance and to compare it with the optimal state This happens through measurement control observation The maintenance is necessary to eliminate possible devia tions...

Страница 17: ...For the external cleaning of the tank it is recommended the use of a cloth with water and neutral detergents avoiding solvents or abrasive products Warning During the cleaning works be carefull not to...

Страница 18: ...ses non dependent from the manufacturer A This guarantee has effect from the date of putting into service GENERAL CONDITIONS OF CONVENTIONAL GUARANTEE F Foranydispute exclusivelythe court of Mantua wi...

Страница 19: ...AND GENERAL CONTROL CLEANING AND GENERAL CONTROL CLEANING AND GENERAL CONTROL CLEANING AND GENERAL CONTROL CLEANING AND GENERAL CONTROL CLEANING AND GENERAL CONTROL CLEANING AND GENERAL CONTROL CLEANI...

Страница 20: ...ascrizione o di stampa Si riserva altres il diritto di apportare ai propri prodotti quelle modifiche che riterr necessarie o utili senza pregiudicarne le caratteristiche essenziali AG S P A 46033 cast...

Отзывы: