12
Flue connection
The flue must have internal dimensions not
exceeding 20 x 20cm or diameter 20 cm; in case
of greater dimensions or poor flue conditions (e.g.
cracks, poor insulation, etc.) it is recommended
to insert a stainless steel pipe in the flue (lining)
of adequate diameter for its entire length, up to
the top.
Check with adequate instruments that there is
proper draft. This type of connection assures flue
gas extraction even in the event of temporary
power outage.
The base of the flue must be fitted with an
inspection port for periodic check up and cleaning,
which must be done yearly.
Ensure a wind-proof cowl is installed according to
regulations in force.
Water connections
Flue gas exhaust connection
Filling up the heat stove
After making all the water connections, fill the
heat stove to check tightness under pressure of
all connections.
venting of any air in the system during this
operation is assured by automatic venting.
The COLD filling pressure of the system must be
1 bar.
Should the system pressure go below the
minimum figure set out above during operation,
the User must use the filling cock to bring it back
to the initial value.
For correct HOT operation of the heat stove,
boiler pressure must be 1.5 bar.
Vent
safety
valve
.it AQ 28/33
CAP BLOCKED
CAP LOOSENED BY
ONE TURN