7
Programming procedure
(only qualified personnel)
To enter parameter programming, hold the key
pressed for about 8 seconds until the first modifiable pa-
rameter (
parametro 0
) appears on the display with the
default value.
Now press the key
and the figure will start flashing.
Change the figure with the keys
and
.
Press
to confirm the figure.
Press the key
for 8 seconds to exit the menu.
For the range of values that can be set according to the
system installed, see chapter 4 of the Installation instruc-
tion booklet (Parameters list / Settable values) page 23.
By pressing the keys
and
, the next parameters
can be viewed in sequence. Set the desired values by
acting as explained previously and, when programming
is completed, confirm all the selections by holding the key
pressed for 8 seconds.
This will transfer all the changes to the non-volatile mem-
ory of the control board.
Resetting the safety thermostat
The safety thermostat is triggered when the boiler
temperature exceeds 100°C and blocks the fan. The
pumps enabled according to the type of diagrams will
continue working.
IMPORTANT: The reset control of the FIREX boiler
safety thermostat is located on the left of the panel
board.
The thermostat resets operation of the wood-fired
boiler.
To access it when the boiler blocks, unscrew the plas-
tic cap with a screwdriver; after resetting the boiler,
put the plastic cap back on.
The safety thermostat can be triggered when the boiler
overheats. This can be solved first of all by lowering the
operating temperature of the boiler (see next point).
If the room thermostat is not requesting the words WINT
OFF WOOD COMB. are displayed, or if there is no demand
for DHW the words SUMMER OFF WOOD COMB.
In Summer mode, the heating system pump is disabled.