Technical features and dimensions
1.4 - OPERATIONAL DATA
For some data (NOZZLES - BURNER GAS PRESSURE - DIAPHRAGMS - INPUTS - GAS CONSUMPTIONS)
refer to paragraph ADAPTATION TO THE USE OF OTHER GAS on page 23.
See Data plate
9.55
0.5
3
8
85
35
10
185.7
0.5
6
13.5
12
9.1
10.1
11.6
13.5
16.3
35 - 55
230/50
4
143
X4D
51
Boiler category
Minimum water low rate in heating circuit (
D
T 20°C)
Minimum pressure in heating circuit
Maximum pressure in heating circuit
Water content of the primary circuit
Maximum operation temperature in heating mode
Minimum operation temperature in heating mode (*)
Expansion vessel total content
Maximum water content of the heating circuit (max. temp. 90°C)
Minimum pressure in the D.H.W. circuit
Maximum pressure in the D.H.W. circuit
Specific D.H.W. flow rate ( t 30°C according to EN 625)
Flow rate of the D.H.W. flow restrictor
Contiunuous D.H.W. production with t 45 K
Contiunuous D.H.W. production with t 40 K
Contiunuous D.H.W. production with t 35 K
Contiunuous D.H.W. production with t 30 K
Contiunuous D.H.W. production with t 25 K
D.H.W. temperature adjustable between
Electrical power supply Tension/Frequency
Supply fuse
Maximum absorbed output
Insulation degree
Net weight (dry)
l/min
bar
bar
l
°C
°C
l
l
bar
bar
l/min.
l/min.
l/min.
l/min.
l/min.
l/min.
l/min.
°C
V-Hz
A (F)
W
IP
kg
Nominal output
Minimum output
Actual water efficiency at 100 % of nominal load
Minimum water efficiency required at 100 % of nominal load
Actual water efficiency at 30 % of nominal load
Minimum water efficiency required at 30 % of nominal load
Star number (according to Efficiency Directive 92/42/CE)
Combustion efficiency at 100 % of nominal load
Combustion efficiency at minimum load
Heat losses through the casing (min. / max.)
Maximum net smoke température (Ts- Ta)
Massive smoke flow rate (min. / max.)
Air exces (lambda)
CO
2
NOx (ponderal value according to EN 297/A3+EN 483)
NOx class (ponderal value according to EN 297/A3 + EN 483)
Chimney heat losses with burner in operation (min./max.)
Chimney heat losses with burner shut-off
kW
kW
%
%
%
%
n.
%
%
%
°C
g/s
%
%
mg/kWh
%
%
DUA plus 30
µ tank
29.95
13.9
93.03
92.95
92.52
90.43
94,78
91,53
1.87 - 1.75
78,7 - 93.7
14.27 - 16.33
41.72
3,8- 8.0
144
3
11.27 - 6.8
0.398
DUA plus 30
(*)
µ tank
1.5 - GENERAL SPECIFICATIONS
(*) Warning: The utilisation of this type of boilers in the "floor heating systems" needs the use of specific equipments (e.g.:
UNICAL Thermic Module) to avoid all risks of smoke condensation within the boiler.