5

User’s operating instructions

By pressing this key for at least 3 seconds
the boiler will operate at the maximum ou-
tput (led 

D

 = illuminated and flashing and

led 

E

 = constantly illuminated).

By briefly pressing this key again (<3 secs.),

the boiler will operate at the minimum ou-
tput (both the leds 

D

 and 

E

 flashing).

By briefly pressing this key again (<3 secs.),
the boiler will operate at the minimum ou-
tput (both the leds 

D

 and 

E

 flashing).

The “chimneysweeper” mode will remain enabled for 15 mi-
nutes.
To disenable the 

“CHIMNEYSWEEPER”

 mode before this set

time has elapsed, press the reset/chimneysweeper key 

“G”

for at least 3 seconds.

System temperature control/pressure gauge

This displays:
- on the upper scale the central heating

hot water flow temperature is indica-
ted.

- On the lower scale the water pressure

in the central heating system is indica-
ted.

- If the pressure is lower then 0,7 bar,

then it will be necessary to restore the
correct pressure by operating the filling
valve when the system is cold and the
boiler not operating

Power On indicator led

This led will illuminate when the boiler is connected to
the electricity supply

Central heating mode indicator led

This led will illuminate when there is a request for
central heating. If simultaneously there is a request
for domestic hot water production, the led will switch
off.

Burner On indicator led

When this led is illuminated it indicates that the burner is fun-
ctioning correctly, both in central heating request mode and in
domestic hot water production mode.

Lock-out indicator led

When this led is illuminated it indicates that the bur-
ner’s safety cut-off device has shut-down the boiler.

Reset key

The function of this key is to reset correct boiler ope-
ration after the cut-off device has shutdown the boiler

(red 

 led indicator illuminated)

If the cut-off device operates more than 3
times, causing boiler shutdown, do not try to
reset the boiler yourself. Contact your nea-
rest Unical authorized After Sales Service
Centre.

Reset key with “Chimneysweeper” mode

WARNING!
This operation can be carried out exclusi-
vely by personnel from authorized After Sa-
les Service centres. The user is NOT autho-
rized to activate the following described
mode.

By pressing this key the “Chimneysweeper”
mode is activated. This means that the boiler
will be forced to operate at the maximum (or
minimum) output so as to permit the adjust-
ment operations and the combustion analysis.

6.2 - CHECK LIST BEFORE COMMISSIONING

THE BOILER

Before commissioning the appliance it is recommended to
check the following points:
-

Check that the On-Off gas valve, positioned upstream of
the boiler, is in the On position..

-

Check that any On-Off valves fitted on the flow and return
pipes for servicing purposes are in the On position.

-

Check that any On-Off valves fitted on the cold water inlet
for servicing purposes are in the On position.

-

Check that the pressure relief valve drainage pipe is con-
nected to the sewage system.

-

Check that the boiler is connected to the electrical supply;

the green indicator led (

) on the control panel must be

illuminated..

-

Check the heating system pressure,  indicated by the pres-
sure gauge. For correct operation the pressure should be
between 0,8 and 1 bar (with the pump not running).
If the pressure falls below 0,7 bar restore the correct pres-
sure by regulating the filling valve when the system is cold
and the boiler not operating (refer to paragraph 6.5).

Содержание ALKON 24 B 60

Страница 1: ...00332926 1st edition 09 2008 ALKON 24 B 60 ALKON 35 B 60 USER SOPERATING INSTRUCTIONS ...

Страница 2: ...s indicated in this guide 3 WATER TREATMENT The hardness of the mains water supply conditions the frequency with which the heat exchanger is cleaned In hard water areas where the main water can exceed 15 f total hardness a scale reducing device is recom mended The choice of this device has to be made taking into consideration the water s characteristics In order to improve the resistance to lime s...

Страница 3: ...agni l apparecchio in modo che possa essere consultato dal nuovo proprietario e o dall installatore Nel caso di danni a persone animali e cose derivanti dalla mancata osservanza delle istruzioni contenute nel presente manuale il costruttore non può essere considerato responsabile 4 INFORMAZIONI DA FORNIRE ALL UTENTE A CURA DELL INSTALLATORE 5 AVVERTENZE PER LA SICUREZZA ATTENZIONE L installazione ...

Страница 4: ...NSTRUCTIONS 6 1 CONTROL PANEL E Burner On indicator led Green F Not active G Reset chimneysweeper mode key H Lock out led indicator Red I System temperature control pressure gauge Summer winter selector Central heating temperature control knob By turning this knob it is possible to choose the following operating modes Summer only DHW production Winter DHW production and central hea ting temperatur...

Страница 5: ...safety cut off device has shut down the boiler Reset key The function of this key is to reset correct boiler ope ration after the cut off device has shutdown the boiler red led indicator illuminated If the cut off device operates more than 3 times causing boiler shutdown do not try to reset the boiler yourself Contact your nea rest Unical authorized After Sales Service Centre Reset key with Chimne...

Страница 6: ...he electrical supply to the boiler the green Power On led is not illumi nated If the boiler will remain shut down for a longer period turn the Domestic hot water production MAX On Off gas cock into the Off position and if fitted turn the cold water supply cock into the Off position In the case of long periods of inactivity of the boiler close the gas and water gate valves Remember that the install...

Страница 7: ...ARNING If the boiler goes into lock out and or the leds continue to flash repeatedly or remain illumi nated do not try to reset the boiler yourself Contact your nearest Unical authorized Af ters Sales Service Centre Burner lock out led constantly illuminated Cause IThe burner s lock out device has intervened due to no gas supply in this case check that the gas service cock is open presence of air ...

Страница 8: ...ag info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...

Отзывы: