Unical 001104 Скачать руководство пользователя страница 6

6

EN

Display      

Kind of problem

Solution

AL01

no ignition

The stove cannot ignite 
at the fi rst start-up

Fill the tank with pellets 
Start up again

AL02

defected NTC sensor         

The ambient sensor is broken 
or not connected to the PCB

Contact an Authorized Assistance Center

AL05

no pellet

The stove switched off 
during the work phase

Fill in the tank with pellets
Clean the brazier and restart the stove

AL06

pressostat

Obstructed fl ue pipe

Clean the fl ue pipe or check that there are no 
obstructed grilles at the exit of the smoke outlet

AL07

thermostat

The stove is overheated

Wait for the stove to cool down. Reset the 
thermostat manually. 

If the problem per-

sists, contact an Authorized Assistance 
Center

AL08

black out

There is no power supply

As soon as the power supply is back, the 
Stove starts a cooling cycle. After completing 
the cycle it starts working automatically

AL09

smoke motor

Smokes extractor blocked 
or broken

Contact an Authorized Assistance Center

AL10

smoke temp.

Smokes temperature too high

Switch off the Stove, allow it to cool down 
and perform ordinary cleaning. 

If the 

problem persists, contact an Authorized 
Assistance Center for cleaning the Stove 
and the fl ue

AL11

smoke probe

The smokes sensor is broken 
or not connected to the PCB

Contact an Authorized Assistance Center

AL12

PBC over temp.

Temperature PCB too high

Switch off the Stove, allow it to cool down 
and perform ordinary cleaning. 

If the 

problem persists, contact an Authorized 
Assistance Center for cleaning the Stove 
and the fl ue

AL13

cochlea error

Faulty cochlea motor

Contact an Authorized Assistance Center

Alarm signal

Technical menu

Main

User

Tech

Tech

NB: The technical menu is a menu reserved for authorized technicians. 
Tampering with the parameters in the technical menu by the end user 
voids the warranty.