Wheel mounting on adapter. (Fig.4.)
Center the wheel in conus sleeves (4) and block by distance sleeves (5) and nut (6).
Eventually the wheel is fixed by tyre tighters (2).
Electrical connection of the wheel balancer
ATTENTION !
Plug the supply cable into the socket 230V/50Hz.
ATTENTION !
SINCE UNEXPECTED WARMING OF FROZEN METAL AND PLASTIC SOLID
GENERATES CONSIDERABLE QUANTITIES OF WATER VAPOUR CONDENSATE, IT IS
FORBIDDEN TO PLUG IN COOLED WHEEL BALANCER TO THE POWER NETWORK
BEFORE THE LAPSE OF 2 TO 3 HOURS REQUIRED TO DRY THE ELECTRONIC
ELEMENTS AND THEIR REACHING THE WORKSHOP TEMPERATURE. FAILURE TO
COMPLY WITH THIS REQUIREMENT MAY CAUSE DAMAGE TO THE WHEEL
BALANCER. AND WITH FAULTY ELECTRICAL INSTALLATION IT MAY CAUSE
ELECTRIC SHOCK.
Hood Mounting (Fig.5)
Screw the hood holder (2)
to machine’s body by two screws M8x80 (5). Screw the hood to
the holder by screws M6x15 (3). Connect the cable to the socket (4) in hood holder (2). The
cable informs about hood position (open-close).