UTP3000C Series User Manual
6
Remote Control
COM setting: set computer COM portsetting as below:
•
Baud Rate: 9600
•
Calibration Bit: None
•
Data Bit: 8
•
Stop Bit: 1
RS232 Interface Definition
Communication protocol V2.0
Order Format: VSET
<
X
>
:
<
NR2
>
1.
VSET: Order Parameter
2.
X: Channel
3.
:Separator
4.
NR2: Parameter
Order Description:
1.
LOCK
<
NR2
>
Function Description:Lock power supply operation panel
Example: LOCK1
Lock power supply operation panel
Example:LOCK0
Unlock power supply operation panel
2.
ISET
<
X
>
:
<
NR2
>
Function Description: Set current value
Example: ISET1:2.225
Set current value as 2.225A
3.
ISET
<
X
>
?
Function Description: Read the set current value
Содержание UTP3300C Series