1. Safety Instructions

This operation manual includes the user guidance and safety instru
-ction when using the tester, please read it before using.

Caution

 ● Before using the tester, please read and understand the operating  
    manual.
 ● Keep the operating manual properly, and let it easy to get it for   
     reference during the process of testing.
 ● When using the tester, user must follow the testing procedure as 
    mentioned in the operating manual.
 ● Carefully read the operating manual regarding the safety information.   

   
 ● Strictly follow all the related safety instructions, otherwise it may  
    cause accidents or damage the tester.

Safety sign “      ” has three meaning in this manual, user has to pay 
the attention to this sign “      ” for operation.

Danger-----identifies conditions and actions that most likely 
                 pose severe or fatal hazard(s)

Warning---identifies conditions and actions that may pose 

                 severe or fatal hazard(s)
Caution---identifies conditions and actions that may cause 

                minor injury or damage to the Tester. 

                                              Danger

 ● This test instrument is suitable for using under single phase 
     230V+10%-15%.(Operational Voltage Scope: 195 – 253 V)
 ● To avoid possible electric shock or personal inquiry, do not use  
    the test t instrument or test leads if they appear damaged or metal 
    part is exposed, or if test instrument is not operating properly. 
    If in doubt, please have  the instrument serviced.

 ● Do not use your finger to touch on any testing cable during the 
    testing ..
 ● Remove the test leads away from the power after the testing 

    completes. Do not keep the test leads connected to the power  

    for a long time after the testing 

                                               Warning

 ● Do not open or disassemble the tester randomly during the 

    measurement, for the high voltage present into the unit may 
    endanger the user. If it needs service repairing, please contact  
    our after-sales services or our agents.
 ● If the test instrument appear abnormal ( for example, no completed 
    display, incorrect calculation, housing damage, noise issue during 
    the measurement etc….).  please contact our after-sales services 
    or our agents.
 ● Do not use the tester if your hands are in wet.

                                                      Caution

 ● Ensure the test lead probe (use only the specified test leads from 
    UNI-T) insert into the corresponding port in order to provide a safe   
    before measurement.  It is recommended not  to use third arties  
    test plead probe on our tester.
 ● Do not expose the tester in extreme temperature and wet environment.
 ● Soft cloth and mild detergent should be used to clean the surface of 
     he tester.  No abrasive and solvent should be used when servicing.
 ● Dry the tester before storing if it is wet.

This Tester has the follow signs,please pay attention to the content  
when using

danger, warning, caution

 double or reinforced insulation 

Grounding                         
CE conforms to Standards of European Union

2. Features

  

●  

Suitable for Use

 on 230V/50Hz single-phase line (operating 

      voltage: 195~253V);

  

●  

Adopts Micro-Processor Chip

 to maintain high accuracy, reliability

      and stability;

  

●  

Wiring Check: 

three –LED indication

      When P-E and P-N green LED are on and red LED is off, the 

      wiring is correct; otherwise it  indicates wrong wiring(reverse P 

      and N or bad grounding);

  

●  

Phase Angle Selection: 

The tests can be performed at positive 

      0  or negative 180  phase angle.

  

●  

Over-Load Indication:

 “OL mS” shows when trip time exceeds 

      Max. test time

  

●  

Auto Data Hold: 

The test results will be maintained for a while after 

      the tests finishes.

  

  

3. Technical  Specifications

3.1  Measuring Range & Accuracy.  (Temperature: 23±5

; Humidity:  

45%~75% RH; Altitude ≤2000m)

UT581:

Functions Voltage(AC) Trip Current(  I

n

)

Trip Time 

(MAX)

Accuracy

Trip Current

Trip Time

X 1/2

X 1

X 5

250mA

(Fast 

Trip)

230V 

(Tolerance:                  

-15%~+10%)

Frequency: 

50Hz

250mA(Fixed)

10 / 20 / 30mA

500mA

10 / 20 / 30 /100 / 

300 mA

10 / 20 / 30 /100 / 

300 /  500mA

1000mS

1000mS

300mS

1000mS 

40 mS

Tolerance: 

-10%~0%

Tolerance:   

0%~+ 10%

Tolerance: 

0%~+ 10%

±0.6% rdg 

±4dgt

UT582:

Functions Voltage(AC) Trip Current(  I

n

)

Trip Time 

(MAX)

Accuracy

Trip Current Trip Time

X 1/2

X 1

X 5

AUTO 

RAMP 

TEST

230V 

(Tolerance:                   

-15%~+10%)

Frequency: 

50Hz

10 / 20 / 30 /100 

/ 300 /  500mA

10 / 20 / 30mA

500mA

10 / 20 / 30 /100 / 

300 mA

10 / 20 / 30 /100 / 

300 /  500mA

1000mS

1000mS

300mS

(RAMP 

increase to 

10%) I

n

 from 

20%~110%     

300*10  mS 

1000mS 

Tolerance: 

-10%~0%

Tolerance:   

0%~+ 10%

Tolerance: 

-10%~+10%

±0.6% rdg 

±4dgt

3.2  Measuring Range (Functions)

  

×1/2--------------------Non-trip test, check RCD sensitivity

×1----------------------Measure trip time

×5----------------------Measure fast trip time at I

n×5 trip current

250mA----------------Measure trip time(for UT581only, Max. test 

                              time up to 40ms)

AUTO RAMP Test---- Measure trip current(for UT582 only)

3.3  Application Standard:
       IEC 61010-1 CAT III 300V, Pollution Degree 2.
       IEC 61557-1,5
       IEC 61010-2-31

  ●  

Auto Ramp Test:

 Test trip current and trip time simultaneously 

      (for UT582 only);

  

●  

Power-Off Warning Indication:

 The buzzer alarms after operating 

      for 3minutes;

  

●  

Power Save and Environment-Friendly: 

Powered directly by 

      tested circuit (Power 230V/50Hz) , no need to use battery;

  ●  

Fused Protection

  ●  

Double or Reinforced Insulation for safe design.

●  

Fixed 250mA Fast Trip(Max.:40ms)(for UT581 only);