![UNI-T UT207A Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/uni-t/ut207a/ut207a_operating-manual_838910031.webp)
30
UT207A/208A/209A Operating Manual
● The meter will zero automatically.
● When the measuring current >1A, press Hz button to toggle between AC
current and frequency measurement mode. But the frequency readings
obtained from this range is only for reference.
● Change to AC:
UT207A/208A: Couple AC and average value response method. UT209A:
Couple AC and True RMS response method. Input sine wave to adjust. Non
sine wave must follow the below data to adjust:
Peak factor: 1.4~2.0, add 1.0% on the stated accuracy.
Peak factor: 2.0~2.5, add 2.5% on the stated accuracy
Peak factor: 2.5~3.0, add 4.0% on the stated accuracy.
Содержание UT207A
Страница 1: ......
Страница 17: ...16 UT207A 208A 209A Operating Manual Measurement Operation A DC AC Voltage Measurement see figure 3 Figure 3 ...
Страница 25: ...24 UT207A 208A 209A Operating Manual Figure 6 ...
Страница 27: ...26 UT207A 208A 209A Operating Manual Figure 7 ...
Страница 29: ...28 UT207A 208A 209A Operating Manual Figure 8 ...
Страница 33: ...32 UT207A 208A 209A Operating Manual Figure 9 ...
Страница 35: ...34 UT207A 208A 209A Operating Manual Figure 10 ...
Страница 47: ...UT207A 208A 209A Operating Manual ...