The meter is designed and manufactured according to IEC61010-1 safety standard, 
and conforms to CAT III 1000V, CAT IV 600V, and pollution degree 2. If the meter 
is used in a manner not specified by the manufacturer, the protection provided 
by the meter may be impaired. 

1. Before use, please check if there is any item which is damaged or behaving 
    abnormally. If any abnormal item (such as bare test lead, damaged meter 
    casing, broken LCD, etc.) is found, please do not use the meter.
2. Do not use the meter if the rear cover or the battery cover is not completely 
    covered up, or it may pose a shock hazard!
3. Damaged test leads must be replaced with ones of the same model or same 
    electrical specifications. 
4. During measurement, do not touch any exposed wires, connectors, unused 
    inputs or circuits being measured.
5. Use caution when working with voltages above AC 30Vrms, 42Vpeak or DC 
    60V. Keep fingers behind the finger guards of the test leads to prevent electric 
    shock.
6. If the range of the measured value cannot be determined, the meter must be 
    operated at the maximum range.
7. Do not apply more than the rated voltage or current marked on the meter 
    between the terminals or between any terminal and earth ground.
8. Place the function dial in the correct position before measurement.
9. Before measuring resistance, diode, continuity, or capacitance, switch off the 
     power supply of the circuit, and fully discharge all capacitors.
10.Before measuring current, make sure the fuses are intact.
11.Do not use or store the meter in high temperature, high humidity, flammable, 
     explosive, or strong magnetic field environments.
12.Do not change the internal circuit of the meter to avoid damage to the meter 
     or user!
13.When “       ” is displayed, please replace the batteries in time to ensure 
     measurement accuracy.
14.Turn off the meter in time after measurement. If the meter is not in use for a 
     long time, please remove the batteries.

IV. Electrical Symbols  

Description

Warning or Caution

Caution, possibility of electric shock 

Both direct and alternating current

Equipment protected throughout by DOUBLE INSULATION 
or REINFORCED INSULATION

Earth (ground) Terminal

Complies with European Union standards

Conforms to UL STD 61010-1, 61010-030, 61010-2-033, Certified 
to CSA STD C22.2 No. 61010-1, 61010-030, 61010-2-033.

It is applicable to testing and measuring circuits connected to the 
distribution part of the building's low-voltage MAINS installation.

It is applicable to testing and measuring circuits connected at 
the source of the building’s low-voltage MAINS installation.

III. Safety Instructions

CAT IV

CAT III

Symbol

Содержание UT161 Series

Страница 1: ...P N 110401109612X 1000V True RMS Digital Multimeter User Manual UT161 Series ...

Страница 2: ...ni Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date This warranty does not apply to damage caused by accident negligence misuse modification contamination or mishandling The dealer shall not be entitled to give any other warranty on behalf of Uni Trend If you need warranty service within the warranty period please contact ...

Страница 3: ...al temperature alarm low battery indication backlight auto power off and NCV functions the meter is an ideal measuring tool for many application fields Open the package box and take out the meter Please double check whether the following items are missing or damaged 1 User manual 1 pc 2 Test leads 1 pair 3 Adapter socket UT161D UT161E 1 pc 4 K type thermocouple UT161D 1 pc 5 USB cable 1 pc 6 Downl...

Страница 4: ... earth ground 8 Place the function dial in the correct position before measurement 9 Before measuring resistance diode continuity or capacitance switch off the power supply of the circuit and fully discharge all capacitors 10 Before measuring current make sure the fuses are intact 11 Do not use or store the meter in high temperature high humidity flammable explosive or strong magnetic field enviro...

Страница 5: ...ode test Continuity test Relative value measurement Resistance units ohm kilohm megaohm Voltage units millivolt volt Current units microampere milliampere ampere Capacitance units nanofarad microfarad millifarad Frequency duty ratio Data transmission Transistor magnification UT161E Non contact voltage detection Peak measurement UT161D UT161E Maximum Minimum measurement Celsius Fahrenheit UT161D Lo...

Страница 6: ...urement Frequency and duty ratio measurement Non contact voltage detection Short press Press a button for less than 2s Long press Press a button for more than 2s 1 Button Short press to switch between functions in each compound function position 2 Button Short press to enter the manual range mode and change the range Long press to exit the manual range mode 3 Button Short press to switch between f...

Страница 7: ...er test 2 DC Voltage Measurement Picture 5 DC Voltage Measurement 1 Insert the red test lead into the or terminal and black test lead into the COM terminal 2 Turn the function dial to the or position 3 Short press the button to switch to DC voltage measurement if SELECT required 4 Connect the test leads with the measured load or power supply in parallel 5 Read the voltage value on the display if t...

Страница 8: ...t is below 10kΩ the error can be ignored 0 1 4 LoZ low impedance ACV Measurement UT161D Picture 7 1 Insert the red test lead into the or terminal and black test lead into COM terminal the 2 Turn the function dial to the position 3 Connect the test leads with the measured load or power supply in parallel 4 Read the voltage value on the display 5 Short press the button to display the frequency duty ...

Страница 9: ...t and use the relative value measurement REL mode leads If the resistance is not less than 0 5Ω when the test leads are short circuited please check if the test leads are loose or abnormal When measuring high resistance it is normal to take a few seconds to stabilize the reading 6 Continuity Test Picture 9 1 Insert the red test lead into the or terminal and black test lead into the COM terminal 2 ...

Страница 10: ...e power supply of the circuit and fully discharge all capacitors 8 Capacitance Measurement Picture 11 1 Insert the red test lead into the or terminal and black test lead into the COM terminal 2 Turn the function dial to the or position 3 Short press the button to switch to capacitance measurement SELECT 4 Touch the probes to the capacitor pins 5 Read the capacitance value on the display after it g...

Страница 11: ...tion of the measured transistor 10 Frequency Duty Ratio Measurement Picture 13 1 Insert the red test lead into the or terminal and black test lead into the COM terminal 2 Turn the function dial to the position 3 Short press the button to switch to frequency duty ratio measurement required if 4 Read the frequency duty ratio value on the display Caution Use caution when working with voltages above A...

Страница 12: ...5 Read the current value on the display if the current is 10A the red indicator light will be on and the buzzer will sound an alarm 6 When measuring AC current short press the button to display the frequency duty ratio of the measured current Caution To prevent possible electric shock fire or personal injury switch off the power supply of the circuit and then connect the meter with the circuit in ...

Страница 13: ... USB communication module into the USB access port of the meter and the LCD will display Picture 17b 3 If USB data transmission is not needed during measurement long press the button or pull out the USB module to disable data transmission and will disappear 4 To recover this function long press the button or insert the USB module 5 The USB communication software can be downloaded from the official...

Страница 14: ... III 1000V CAT IV 600V 19 Certification CE ETL 20 Pollution degree 2 21 Information of usage Indoor and outdoor 2 Electrical Specifications Accuracy a of reading b digits 1 year warranty Ambient temperature 23 C 5 C 73 4 F 9 F Relative humidity 75 Caution To ensure measurement accuracy the operating temperature should be within 18 C 28 C and the fluctuation range should be within 1 C When the temp...

Страница 15: ... counts and can only be 1 at 22000 counts The additional error should be added according to the crest factor of a non sinusoidal wave as follows UT161E a Add 4 when crest factor is 1 2 b Add 5 when crest factor is 2 2 5 c Add 7 when crest factor is 2 5 3 Frequency measurement range 40Hz 500Hz UT161B 40Hz 1kHz UT161D 40Hz 10kHz UT161E input amplitude 10 of voltage range Duty ratio is for reference ...

Страница 16: ...ell connected circuit Resistance 50Ω audio visual alarm Open circuit voltage About 3V For normal diodes the buzzer will beep once For short circuit the buzzer will beep for a long time Resolution 0 1Ω 0 001V Range Overload protection 1000V When the forward voltage drop is within 0 12V 2V the buzzer will beep once When the forward voltage drop is 0 12V the buzzer will beep for a long time 6 Transis...

Страница 17: ...s 8 Temperature Range 40 0 C 0 300 C 300 1000 C 40 32 F 32 572 F 572 1832 F 40 1000 C 40 1832 F Accuracy 1 0 3 C 1 0 2 C 1 0 3 C 1 0 6 F 1 0 4 F 1 0 6 F Resolution 0 1 C 1 C 0 2 F 2 F The measured temperature should be less than 230 C 446 F 9 DC Current UT161E Accuracy Range 220 00μA 2200 0μA 22 000mA 220 00mA 20 000A Resolution 0 01μA 0 1μA 1μA 10μA 1mA 0 5 10 1 2 50 UT161B UT161D Accuracy Range ...

Страница 18: ...a Add 4 when crest factor is 1 2 b Add 5 when crest factor is 2 2 5 c Add 7 when crest factor is 2 5 3 The AC crest factor can be 2 0 at 10000 counts and can only be 1 at 22000 counts The additional error should be added according to the crest factor of a non sinusoidal wave as follows UT161E a Add 4 when crest factor is 1 2 b Add 5 when crest factor is 2 2 5 c Add 7 when crest factor is 2 5 3 Fre...

Страница 19: ...20MΩ mAµA 35 36 1 Clean the meter casing with a damp cloth and mild detergent Do not use abrasives or solvents 2 If there is any malfunction stop using the meter and send it for maintenance 3 The maintenance and service must be implemented by qualified professionals or designated departments 4 Resistance measurement can be used to check the built in 600mA and 11A fuses Operation Picture 18a Insert...

Отзывы: