53
UT108/109 OPERATING MANUAL
UT108/109 OPERATING MANUAL
54
G. Voltage Drop Testing
Test the voltage drops caused by the switch, cable, solenoid or connector. Any abnormal
voltage drop generally results from an additional resistance. The resistance will restrict
the currents upon the start of the engine, leading to the reduction of the load voltage of the
battery and the slow-down of the start of the engine.
1. Cut off the ignition system so as to disable the start of the automobile.
Cut off the main ignition coil, shunt coil, cam and starting sensor so as to cut off the
ignition system. Operate by reference to the automotive manual.
2. Set the rotary switch to
DCmV
or
DCV
. Insert the red test lead into the
A
terminal and
the black test lead into the
COM
terminal.
3. Refer to the LOSS typical trigger voltage circuit. (See figure 15)
Test the voltage between any of the following pairs of points respectively:
1&2, 2&3, 4&5, 5&6, 6&7, 7&8, 8&9, 8&10
Component
Voltage
Switch 300 mV
Lead
200 mV
Grounding
100 mV
Battery Lead Connector 50 mV
Wiring 0.0 V
Содержание UT108
Страница 1: ...P N 110401102526 ...
Страница 2: ...Operating Manual UT108 109 Handheld Automotive Multi Purpose Meters ...
Страница 20: ...UT108 109 OPERATING MANUAL 18 Display Symbols see figure 3 Figure 3 ...
Страница 24: ...UT108 109 OPERATING MANUAL 22 Figure 4 ...
Страница 26: ...UT108 109 OPERATING MANUAL 24 Figure 5 ...
Страница 29: ...27 UT108 109 OPERATING MANUAL Figure 6 ...
Страница 34: ...UT108 109 OPERATING MANUAL 32 Figure 8 ...
Страница 37: ...35 UT108 109 OPERATING MANUAL Figure 9 ...
Страница 39: ...37 UT108 109 OPERATING MANUAL Figure 10 ...
Страница 41: ...39 UT108 109 OPERATING MANUAL Figure 11 ...
Страница 43: ...41 UT108 109 OPERATING MANUAL Figure 12 ...
Страница 45: ...43 UT108 109 OPERATING MANUAL Figure 13 ...
Страница 61: ...59 UT108 109 OPERATING MANUAL Figure 16 ...
Страница 63: ...61 UT108 109 OPERATING MANUAL Figure 17 ...
Страница 65: ...63 UT108 109 OPERATING MANUAL Figure 18 ...
Страница 68: ...UT108 109 OPERATING MANUAL 66 Figure 20 ...
Страница 70: ...UT108 109 OPERATING MANUAL 68 Figure 21 general normal resistance is less than or equal to 10 Ω ...
Страница 76: ...UT108 109 OPERATING MANUAL 74 Figure 24 ...
Страница 79: ...77 UT108 109 OPERATING MANUAL Figure 26 Figure 25 ...
Страница 93: ...91 UT108 109 OPERATING MANUAL Figure 27 ...
Страница 95: ......