5. General View of Product 

 

 

 

 

Содержание UT-P43 Series

Страница 1: ...UT P43 UT P44 Series Current Probe Instruction Manual ...

Страница 2: ...1 UT P43 UT P44 Series Current Probe Instruction Manual Please read the instruction manual carefully to avoid injury and prevent damage to this product Ver 1 03 2021 5 17 ...

Страница 3: ...provide a replacement in exchange for the defective product Parts modules and replacement products used by UNI T for warranty work may be new or reconditioned to like new performance All replaced parts modules and products become the property of UNI T This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care THIS WARRANTY IS...

Страница 4: ...Table of contents 1 Safety Summary 4 2 Brief Introduction 5 3 Main Specification 6 4 Unpacking and Preparation for Use 8 5 General View of Product 9 6 General View of Accessories 10 7 Operating Basics 11 ...

Страница 5: ...isconnect probes while they are connected to a voltage source Ground the product This product is indirectly grounded through the grounding conductor of the mainframe power cord To avoid electric shock the grounding conductor must be connected to earth ground Before making connections to the input or output terminals of the product ensure that the product is properly grounded Do not operate without...

Страница 6: ...s current probe can be used to do power analysis of high frequency signal with our UT P35 UT P36 Series high voltage isolating probe The delay time of any two probes is less than 1ns UT P43 UT P44 series current probe is small and robust It has very high stability reliability and accuracy It may be used at the following location usually Measure current without connect to circuit Power analysis Swi...

Страница 7: ... AC 40A DC peak AC Current transfer ratio 100mV A 50mV A Accuracy 3 Max measurable pulse current 50A Tp 10μs Max voltage on uninsulated wire 400V DC peak AC Noise 1mVrms Linearity 1 Delay time 20ns 1ns AC adapter output DC9V 1000mA AC adapter input AC100 240V 50 60Hz Typical mechanical specification Jaw opening 4 5mm Output cable length About 130cm ...

Страница 8: ...y 188 40 24 mm Weight probe only 150g Environment Specification Operating temperature 0 40 Storing temperature 10 45 Operating humidity 85 RH Storing humidity 90 RH Operating altitude 3000m Storing altitude 12000m ...

Страница 9: ...ediately Packing list Current probe 1pcs Instruction manual 1pcs AC adapter 1pcs 4 2 Preparation for use Please check the line voltage prior to connect the AC adapter to the electric outlet The line voltage should be coincident the following list If the incorrect line voltage is used it will damage the product and the AC adapter AC adapter input voltage Frequency AC100V 240V 50 60Hz Warning Use on...

Страница 10: ...9 5 General View of Product ...

Страница 11: ...10 6 General View of Accessories The product include an accessories An AC adapter ...

Страница 12: ...terminal or the oscilloscope Set the input channel to the highest sensitivity and set a zero reference point With the probe jaw empty push the slide on the probe until it locks completely Press the DEGAUSS button Adjust the BALANCE thumbwheel until the displayed signal is zero c Slide the lid of probe jaw and open the probe jaw then put the measured wire into the probe jaw and close the probe jaw ...

Страница 13: ...tivity of your current probe by winding several turns of the wire under test around the probe as shown in Figure 7 2 7 3 Troubleshooting The Power LED does not remain lit Check that the AC adapter is plugged in and functional The measured waveform can t be displayed right and stability Check that the probe jaw and keep it closed completely Check the probe connection to the oscilloscope Change a di...

Страница 14: ...13 ...