User’s Manual                                                                                                                                                UDP6722 Programmable DC Power Supply 

Instruments.uni-trend.com                                                                                                                                                                                     

 

26

 / 

32

 

 

13.1    File Management (local)   

In <Wage> page, press [File] under the screen, or in <measure> page, press [file] under the screen, we will enter 
the file <Local> page. 

 

 

 

If USB is inserted, press <Udisk File> shortcut key to manage the file in USB. By turning the rotary knob or 
pressing arrow keys to enter the following table. 

 

Shortcut key of

 

file management 

Shortcut Key 

Setting 

Description 

No. 

0-39 

The number of saved file, number 0 is the default file and 
cannot be deleted. 

Load 

Loading the file in this line, the current list setup will lost. 

Save 

Save the setup into this line file. 
Blank line: create a new list file   
Existing file: overlay the current file and the name will not 
change. 

Delete 

Delete the current file and the default file cannot be deleted. 

Rename 

Rename the current file and the default file cannot be changd. 
The way of rename the file can refer to Rename in List File. 

Display the subordinate shortcut key menu. 

PowerOnLoad 

Off,On 

On:  The  instrument  will  recall  the  file  after  the  instrument 
boots up. 
If the boot recalling of this line is cancled, the default file wibb 
be enable boot recalling. 

AutoSave 

Off,On 

On: The setup will save in the line of the corresponding file in 
real-time.   
Only the file that boot recalling is enabled can be automatic 
saved. 

Copy Udisk 

Copy this file to USB, in the root directory of 
UDP6722\CONFIG, the suffix is *.STA. 

Display the previous shortcut key menu. 

           

Содержание UDP6722

Страница 1: ...User s Manual UDP6722 Programmable DC Power Supply...

Страница 2: ...y If the product is proved to be defective within the warranty period UNI T reserves the rights to either repair the defective product without charging of parts and labor or exchange the defected prod...

Страница 3: ...I T products are protected by patent rights in China and foreign countries including issued and pending patents UNI T reserves the rights to any product specification and pricing changes UNI T reserve...

Страница 4: ...ain operation process operation method or similar Product damage or loss of important data may occur if the rules in the Caution statement are not properly executed or observed Do not proceed to the n...

Страница 5: ...equipment directly connected to the distribution board and circuit between the distribution board and the socket three phase distributor circuit includes a single commercial lighting circuit Fixed eq...

Страница 6: ...sure to ground this product before it is powered on AC power supply Please use the AC power supply specified for this device Please use the power cord approved by your country and confirm that the ins...

Страница 7: ...onnel of UNI T for testing Any maintenance adjustment or parts replacement must be done by the relevant personnel of UNI T Cooling Do not block the ventilation holes at the side and back of this devic...

Страница 8: ...appliances maintenance 3 1 Specifications and Functions Model Output Range UDP6722 0V 80V 0A 20A 0W 400W 3 2 Accuracy of Instrument Rated output voltage 0 80V Rated output current 0 20A Output power...

Страница 9: ...ODBUS Power voltage AC 220V 10 Frequency 50Hz 60Hz Size W H D 214X88X393mm Weight 4 65 kg 3 3 Main Characteristics 4 3 inch TFT LCD Full range high resolution Low ripple and noise Remote sensing funct...

Страница 10: ...ng to the display menu on the screen 3 Output port Power output port on front panel 4 Arrow keys To move the cursor 5 Rotary knob To move the cursor and confirm the function 6 Numerical keyboard To in...

Страница 11: ...50V 5 Cooling fans Please leave space for cooling 6 Power output port on rear panel It has compensation function If only to use the port on front panel it should use the input terminal attached with t...

Страница 12: ...To prevent electric shock please make sure that the power line is securely connect to the ground 5 3 Operation Environment UDP6722 DC power supply is recommended for use under the following environme...

Страница 13: ...4 Lift Position 5 6 Daily Checking To avoid the accident please check the instrument before using 1 The instrument s input power should conform to the specification and the power configuration should...

Страница 14: ...the load end is equal to the voltage set by the power supply Figure 5 5 Remote Compensation on Rear Panel 5 8 1 Wiring of Remote Sensing 1 Turn off the output of power 2 Remove the shortcircuit plate...

Страница 15: ...ck to Measure page Figure 6 1 Measure Page Measure Page No Item Description 1 Functional key Option of shortcut key displayed in the screen 2 Data display Display the real time voltage current and pow...

Страница 16: ...ot lock all keys can be use Key has locked only output and unlock key can be use 8 Sound key has turned on Sound key has turned off 9 Time display 10 Voltage and current value measure page is not disp...

Страница 17: ...after the instrument boots up The default setting is Off 7 List Setup List mode is used to set the voltage and current value and output time for every steps To complete the various kinds of output cha...

Страница 18: ...umber the default is 1 Repeat 1 9999 Times of test cycly the default is 1 Finish Stop Hold Stop stop the output when the test is finished Hold output the last test item when the test is finished Enabl...

Страница 19: ...after press this key Step 0 199 Press Step key and then rotate rotary knob or use keyboard to input the line number Voltage 0 85 00V Press Voltage key and then rotate rotary knob or use keyboard to i...

Страница 20: ...d Load Loading the file in this line the current list setup will lost Save Save the list setup into this line file Blank line create a new list file Existing file overlay the current file and the name...

Страница 21: ...cut key menu 9 2 List File USB Press Udisk File key to enter List file Udisk Figure 9 2 List File Udisk If press Local File shortcut key or plug out USB the interface will switch to local page File op...

Страница 22: ...is 1 Repeat 1 9999 Times of test cycly the default is 1 Finish Stop Hold Stop stop the output when the test is finished Hold output the last test item when the test is finished Enable Off On Whether t...

Страница 23: ...Step key and then rotate rotary knob or use keyboard to input the line number On Off Press this key can step through On and Off in this line On Turn on the voltage output of this step Off Turn off th...

Страница 24: ...e overlay the current file and the name will not change Delete Delete the current file and the default file cannot be deleted Rename Rename the current file and the default file cannot be changd The w...

Страница 25: ...upports the operating of load save delete and rename 12 Wave Display Press Wave key to display the currently output wave of voltage current and power The wave refreshes once per 0 1s Figure 12 1 Wave...

Страница 26: ...this line file Blank line create a new list file Existing file overlay the current file and the name will not change Delete Delete the current file and the default file cannot be deleted Rename Renam...

Страница 27: ...is same as Local file 14 System Setup Menu Press Menu key to enter System page System Setup Item Setting Description Language English Chinese Interface language the default is simplified Chinese Date...

Страница 28: ...0 57600 115200 The baud rate of RS232 RS485 and USB bus IP address IP address when connecting LAN bus IP port 502 Port number of LAN bus it cannot be changed Shortcut key at the bottom of the screen M...

Страница 29: ...Common RS 232 Signal Signal Abbreviation Pin of 25 core connector Pin of 9 core connector Request To Send RTS 4 7 Clear To Send CTS 5 8 Data Set Ready DSR 6 6 Data Carrier Detect DCD 8 1 Data Terminal...

Страница 30: ...on 5 GND 8 485A 9 485B If user uses Modbus protocol it should set the local address 15 3 LAN Port Setup Figure 14 2 LAN Port on Rear Panel Indicator of LAN port LED State Meaning Green Illuminated Con...

Страница 31: ...t Caution Keep sprays liquids and solvents away from the instrument or probe to avoid damaging the instrument or probe 2 Cleaning Check the instrument frequently according to the operating condition F...

Страница 32: ...mit provided by this summary or other applicable insurance guarantee UNI T does not provide any other explicit or implied guarantee including but not limited to the product trading and special purpose...

Отзывы: