SETUP

INSPECTION

 

Report any transport damage immediately to the carrier and your vendor. Initiate a freight claim with 
the carrier. The manufacturer is not responsible for freight damage.

• Accessories:
 

• 

Manual   

 

 

•       Coag-Kleen FP, flocculant granules (WF Model only)

 

• 

Air Blow Gun 

 

 

•       Aqua-Kleen Cleaner

 

•  

Whip LIne Coupler

PLACEMENT AND AIR SUPPLY

•  Mount the unit to a wall (hardware not included) in a Spray Booth or another convenient location in 

the shop.

•  Remove the cover on the "Air Input" (right side of machine) and attach an air supply adapter (not sup-

plied).

•  Remove the Air Blow Gun from the acessories bag and place it onto the bracket on the right side of 

the unit. Connect the air supply tube (blue) to the Air Blow Gun Fitting by inserting the tube. To dis-
connect the tube, push down on the collar and pull the tube out.

UM80W, WF and WA (Water) Models

• Attach the Whip Line Coupler to the orange line on the left side of machine and to your spray gun using      
  a  a quick connect fitting (not supplied) on the Spray Gun.

UM80S (Solvent) Model
• Connect the air supply tube (blue) to the blue fitting by inserting the tube. To disconnect, push down on    
  the collar and pull the tube out.

CAUTION

•  The air supply must be free from contaminants such as water, dust, rust, tar, grease etc. 
•  To prevent damage to the Diaphragm Pump an internal Air Pressure Regulator has been installed to 

limit the air pressure. The pressure must be maintained at 60 PSI for waterborne units and 85 PSI for 
the UM80S. Do not install a second air pressure regulator.

PAIL SETUP and ADDITION OF UNI-RAM AQUA-KLEEN

Aqua-Kleen is a state-of-the-art cleaning additive with an enhanced corrosion inhibitor for optimal protec-
tion of spray guns.

UM80W / UM80WA 
Two 5-litre bottle-type containers are included with the unit.

•  Fill one container with clean water and add half of a bottle of Uni-ram Aqua Kleen.

INTRODUCTION

Uni-ram holds many patents on designs used in its innovative products. Every machine is tested 
for compliance with Quality Assurance standards. Follow the directions in this manual under Setup, 
Operation and Maintenance in order to operate this machine safely and effectively. Not following these 
instruction can lead to malfunction or damage to the machine. Follow directions under the section 
below, Cautions and Warnings and on labels attached to the machine. Ensure that the manual is read-
ily available to the operator at all times. If you have any questions about the operation of this machine, 
call your distributor or a Uni-ram Service Engineer: 

North America: Uni-ram Technical Service 1-800-417- 9133

Other Continents: Contact Your Supplier

Содержание UM80 Series

Страница 1: ...0 SERIES WALL MOUNT SPRAY GUN CLEANERS WATER BORNE UM80W UM80WA UM80WF SOLVENT BORNE UM80S UNI RAM CORPORATION ONTARIO CANADA CAUTION DO NOT USE WATER BORNE UNITS WITH SOLVENT BORNE PAINT OR SOLVENT B...

Страница 2: ...N The air supply must be free from contaminants such as water dust rust tar grease etc To prevent damage to the Diaphragm Pump an internal Air Pressure Regulator has been installed to limit the air pr...

Страница 3: ...ube thick into it Place the pail under the unit Replace the dirty solvent with clean solvent when needed CLEANING SELECTOR KNOB Position the long arm of the selector knob in the verticle position and...

Страница 4: ...MANUAL WALL MOUNT WATERBORNE GUN CLEANERS UM80 SERIES REVISED 2015 5 30 4 UM80W UM80WA UM80W UM80WA UM80S UM80S FRONT RIGHT SIDE...

Страница 5: ...UTION MAKE SURE THE GUNS ARE COMPLETELY DRY AFTER USE FLOCCULATION WF Model Only The dirty water from cleaning accumulates in the flocculation reservoir during use When the Wash Pail is empty follow t...

Страница 6: ...MANUAL WALL MOUNT WATERBORNE GUN CLEANERS UM80 SERIES REVISED 2015 5 30 6 UM80WA HAS ADDTIONAL AIR OUTLET FOR EXTERNAL FLOCCULATION UM80W UM80WA UM80S LEFT SIDE...

Страница 7: ...t cycling the spool valve has stalled due to a blocked air passage Follow the procedure below to clear the blockage Connect a blow gun to an 60 PSI source Locate the blue hose that extends from the ai...

Страница 8: ...q uid Line Replace pump WASH LIQUID DOES NOT FLOW PUMP DOES NOT MAKE A NOISE Pump leaks Replace pump Blockage in air passage Follow Procedure 3 Blocked Passage in Air Line UM80WF ONLY FILTERED WATER I...

Страница 9: ...9 MANUAL WALL MOUNT WATERBORNE GUN CLEANERS UM80 SERIES REVISED 2015 5 30 FLOW DIAGRAM UM80W WA Model not shown Use the diagram to trace the flow of compressed air and water...

Страница 10: ...MANUAL WALL MOUNT WATERBORNE GUN CLEANERS UM80 SERIES REVISED 2015 5 30 10 FLOW DIAGRAM UM80WF Use the diagram to trace the flow of compressed air and water...

Страница 11: ...11 MANUAL WALL MOUNT WATERBORNE GUN CLEANERS UM80 SERIES REVISED 2015 5 30 FLOW DIAGRAM UM80S Use the diagram to trace the flow of compressed air and water...

Страница 12: ...ER 102 8200 COAG KLEEN FLOCCULANT 102 8300 FILTER BAG PRIMARY 102 8125 FILTER BAG SECONDARY 102 8126 FILTER HOLDER 102 8120 WASH PAIL UM80WF ONLY 103 8111P 5 LITRE BOTTLE TYPE CONTAINER 103 8111B WASH...

Страница 13: ...a new pump free of charge and arrange for the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the pu...

Отзывы: