Uni-ram UG5000E Скачать руководство пользователя страница 3

3

MANUAL - SPRAY GUN CLEANERS - UG5000 SERIES

Revision 2007-11

INTRODUCTION

Uni-ram holds many patents on designs used in its innovative products. Every machine is rigorously
tested for compliance with stringent Quality Assurance standards. Follow the directions in this manual
under Setup, Operation and Maintenance in order to operate this machine safely and effectively. Not
following these instruction can lead to malfunction or damage to the machine. Follow directions under
the section below, Cautions and Warnings and on labels attached to the machine. Ensure that the
manual is readily available for the operator at all times. If you have any questions about the operation
of this machine, call your distributor or a Uni-Ram Service Engineer.

CAUTIONS AND WARNINGS

Always disconnect this machine from power sources before performing maintenance

Do not smoke or use near open flames, sparks or heat.

• 

Ground pails and cabinet using supplied grounding wires

FEATURES AND STRUCTURE OF SOLVENT SPRAY GUN CLEANER

UG5000DVM - NO PAILS INCLUDED
UG5000E IS SIMILAR AS UG5000DVM AND PAILS ARE INCLUDED

UG5500E IS SIMILAR AS UG5000E AND HOSE CLEANING IS INCLUDED

FEATURES 

COMBINATION OF SOLVENT SPRAY GUN CLEANER UG4000DVM AND UG3000DA

UG4000DVM

HAS AUTOMATIC WASH, AUTOMATIC AIR FLUSH, AUTOMATIC SOLVENT RINSE,

AUTOMATIC FUME VENTING, MANUAL RINSE W. BRUSH, STAINLESS STEEL TANK AND LID, 2
GUNS CLEANED, 14 JETS, RINSE PUMP AND TWO -19L HDP PAILS

UG3000DA

HAS AUTOMATIC WASH, AUTOMATIC AIR FLUSH,FUME VENTING (OPTION), STAIN-

LESS STEEL TANK ANDHIGH DOOM LID, 2-GUNS CLEANED, 14 JETS AND ONE 19 L TOP
CLOSED HDP PAIL.

North America:

Uni-ram Technical Service

1-800-417- 9133

Other Continents:

Contact Your Supplier

3

Содержание UG5000E

Страница 1: ...LVENT SPRAY GUN CLEANERS UG5000E UG5000DVM AND UG5500E USA 4 788 836 CANADA USA 5 213 117 ENGLAND EUROPE 0300248 ITALY SWEDEN 0300248 GERMANY FRANCE 8110528 0 JAPAN UNI RAM CORPORATION ONTARIO CANADA...

Страница 2: ...T PAIL SETUP 6 GROUND WIRE INSTALLATION 7 OPERATION PRE CLEAN 7 CLEANING SPRAY GUNS AND CUPS 8 USING THE MANUAL WASH and MANUAL RINSE FEATURES 8 HOSE CLEANING ONLY UG5500E 8 AFTER CLEANING 8 DAILY MAI...

Страница 3: ...AUTIONS AND WARNINGS Always disconnect this machine from power sources before performing maintenance Do not smoke or use near open flames sparks or heat Ground pails and cabinet using supplied groundi...

Страница 4: ...T NOT SHOWN GROUND WIRE INSIDE ONE FOR RIENS PUMP AND ONE FOR EACH SUCTION PIPE VENT TANK UG3000DA AUTO WASH TIMER AIR RINSE CLEAN RINSE ADJUSTABLE FOOT FOOT PEDAL FOR MANUAL RINSE UG4000 DVM NOT SHOW...

Страница 5: ...ing contact your supplier LOCATION Position in a well ventilated area away from sparks heat and open flames LEVELING VENT AND AIR SUPPLY Level the machine using the adjustable legs Attach a vent hose...

Страница 6: ...e Suction Pipe and the Rinse Pump Cut the strap holding them together Do not cut the other straps holding the black and blue tubes The Suction Pipe is shown in the section Replacement Parts Inside rig...

Страница 7: ...the cabinet to an external grounded object 2nd ground wire is connected to suction pipe left UG4000DVM 3rd connected to rinse pump and 4th one connected to suction pipe right UG3000DA OPERATION UG400...

Страница 8: ...his quanti ty is usually sufficient to clean the inside pasages of the spray guns USING THE MANUAL WASH and MANUAL RINSE FEATURES For models with manual wash brush open the lid and step on the foot pe...

Страница 9: ...t the Suction Pipe from the Drain Valve and remove the pipe from the pail Move the pail out of the cabinet and recycle or dispose of the wash solvent Remove the Rinse Pump from the other pail move the...

Страница 10: ...Follow Procedure 4 Blocked Passage in Solvent Line WASH SOLVENT OR WATER DOES NOT FLOW AND PUMP MAKES A HISSING SOUND Water in air line causes pump to stall Follow Procedure 2 Blockage in Air Passage...

Страница 11: ...int used and for Automatic Spray Gun Cleaners Increase air pressure to a minimum of 85 PSI Remove and clean by blowing air through the jets If not successful replace GUNS NOT CLEAN WASH SOLVENT IS MIL...

Страница 12: ...due to a blocked air passage Follow the procedure below to clear the blockage Connect a blow gun to an 85 PSI source Locate the blue hose that extends from the air exhaust port of the diaphragm pump...

Страница 13: ...13 FLOW DIAGRAM Shows the flow of solvent and compressed air MANUAL SPRAY GUN CLEANERS UG5000 SERIES Revision 2007 11...

Страница 14: ...10 171 TANK DRAIN VALVE 110 356 TAPER NOZZLE 100 350 SPRAY JETS 140 361F DELIVERY TUBE ASSY WITHOUT JETS 120 318 HANDLE 144 390 FLOW THROUGH BRUSH ASSY INSIDE DETAIL OF GUN CLEANER TANK SOLVENT DETAIL...

Страница 15: ...n 110 430 Nozzle Adapter All models Push On 110 430MJ Nozzle Adapter SATA Mini Jet Threaded 110 430MJP Nozzle Adapter SATA Mini Jet Push On 110 430L1 Nozzle Adapter Threaded SATA 0 6 1 0 litre cups 11...

Страница 16: ...or the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the purchaser stores handles or uses the produ...

Отзывы: