Uni-P Pro 200X Dehumidifier

Installation, Operation & Service Instructions

Uni-P Pro 200X Dehumidifier

Installation, Operation & Service Instructions

11

Pump Alarm- E4 Error Code

**

UNIT WILL NOT FUNCTION UNTIL ERROR CODE IS CLEARED

.

If E4 (pump alarm) is shown on the display, complete the following steps:

Troubleshooting

 

 

 

 

 

 

Display is Blank

No Airflow

Error Code:E1

Error Code:E4

Error Code:LO

Error Code:HI

Tripped GFCI 

Outlet or Breaker

Cause

Solution

Poor Connection

Power Outage

Filter is dirty

Air Inlet or Outlet 

is Blocked

Humidity Sensor or 

Communication Error

Problem with Pump

Room Temperature 

is below 33

Room Temperature 

is above 105

Not a Dedicated Circuit

Defective GFCI Outlet

Dirt, Dust, or 

Moisture on Outlet

 

Lightning or Externa 

Electrical Surge

Possible Dehumidifier 

Issue

Verify that both ends of the 

cord are plugged in

Reset

 

power

Clean the Filter

Clean the

 

blockage

Check to ensure that the sensor wire 
is connected at both ends. if no issues 
are visible, the sensor may be faulty.

Verify that the pump is properly 
installed and functioning. If so, unplug 
the unit for two minutes,then restart.

Increase the room temperature so it is 
within operating range (above 33

). If 

error still displays, check sensor.

Decrease the room temperature so it is 
within operating range (below 105

).

If error stille displays, check the 
sensor

Identify all sources connected to outlet 
and confirm source of trip.If it is 
dehumidifier, contact technical 
support. If not, move dehumidifier to 
dedicated circuit for future use.

Replace Outlet

Clean or Replace Outlet as necessary

Reset or Replace Breaker/GFCI, as 
necessary

If none of above options work, contact 
technical support

1. Reset the unit by unplugging the power cord and then reconnecting it.

2. Manually check to see if the pump is operational by pressing the drain button. Check

if the pump energizes and de-energizes properly. Additionally, check to see if any water

purged from the system.

3. If you haven’t cleaned the system recently, check the discharge line for an obstruction,

then clean as described in the Maintenance section.

4. Replace the hose and/or pump, if maintenance alone isn’t sufficient.

Spare Parts

Fan Components

 External Components

Cables

Duct + Ventilation Accessories

N-100

N-101

N-102

N-1209

N-1206

N-1208

N-1207

Main Control Board

Display Board

RH/Temp. Sensor

Fan Motor

Complete Fan Assembly

Fan Capacitor

N-1210

N-1211

N-1205

N-1200

N-1201

N-1202

N-1203

N-125

Prefilter

MERV 8

HEPA

Carbon Filter

Foot adjustable

Display/Control

Inernal Components

N-120

N-121

N-122

Temp/RH Sensor Cable

Display Ribbon Cable

Ca

Т: 5 Port Internal Cable

N-1204

Supply Duict Collar 

Assembly

Compressor

Compressor Capacitor

Coil Assembly

Condensate Pump

Assembly

Symptom

Содержание Pro 200X

Страница 1: ...Uni P Pro 200X Dehumdifiers Installation Operation Service Instructions Add 4240 Latham Street Suite D Riverside CA 92501 Tel 888 990 7469 E mail sales unipdry com READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ...ctions you will typically need to test the operation of the trip circuit monthly For ease of testing and operation it may be helpful to put the test switch and indicator lights in a convenient locatio...

Страница 3: ...nlet needs a minimum of 12 clearance and the discharge requires a minimum of 36 clearance Unipdry dehumidifiers are only intended for operation when the unit is upright and level with the feet on the...

Страница 4: ...lly open at the accessory float switch If an E4 error occurs immediately switch the wiring to N C normally closed on external switch You may need to unplug the unit to reset the error code 6 Auxillary...

Страница 5: ...l is being utilized The symbol on the display indicates the sensor on the dehumidifier is being utilized 4 Temperature The T button changes the temperature reading on your remote The remote comes from...

Страница 6: ...r such as WEB Coil Cleaner Handle Side Panel Filter Cover Control Panel Pre Filter Discharge Grille Power Cord Auxiliary Terminals Drain Hose Connection a Remove prefilter from inlet of machine b Vacu...

Страница 7: ...over so you have access to the pump 3 Remove the pump head from the reservoir by unscrewing the screw Wipe reservoir clean with a paper towel 4 Reassemble pump 5 Mix a 16 ounce solution of bleach 1 oz...

Страница 8: ...ture so it is within operating range below 105 If error stille displays check the sensor Identify all sources connected to outlet and confirm source of trip If it is dehumidifier contact technical sup...

Страница 9: ...ontact Unipdry Tech Support by phone 888 990 7469 to receive a Return Authorization RA number 3 Once an RA has been issued it is the customer s job to bring the unit to a certified repair center If th...

Отзывы: