1. Audio Inputs
1.1 Mic Inputs / Priority
The input sensivity of these MIC inputs (35, 37, 39, 41) can be adjusted by the
separate GAIN controls (36, 38, 40, 42) in the range of 5 – 300mV.
Every input has separate HI and LO tone controls (12, 14, 16, 18) at the front, that
allow for frequency adjustment if necessary.
The input impedance is 600 ohms.
The PHANTOM switch (30) allows activation of a 48V phantom power in case of
using an electret mic. An activated phantom power is indicated by the red LED next
to the PHANTOM switch (30).
The dip switches (27) allow to activate a VOX controlled priority for the particular MIC
input and results in an automatic muting of the AUX inputs (43, 33, 45, 1).
Muting from MIC 1
Muting from MIC 2
Muting from MIC 3
Muting from MIC 4
1.2 Aux Inputs
Connect your AUX sources here (43, 44, 45, 1).
The input sensivity is 775mV at 47kohms.
The inputs can be selected by the AUX selector buttons (7) at the front of the unit.
The input has HI and LO tone controls (20) at the front that allow for frequency
adjustment if necessary.
1.3 Connector for Paging Station
At this input (34) you can connect a paging station UPM 8001.
The volume of the announcement can be adjusted with the MIC 1 control (11).
A 2-tone pre chime can be activated by switch (26).
Attention:
The connector always supplies 24V phantom power.
A
simultaneous
use of the PAGING STATION input (34) and the MIC 1 input (35) is
not possible.
Vorgong an
Vorgong aus
1.4 Internal Chime/Alarm and Priority Output
By shorting the contacts DIN ALARM START and GROUND you can trigger the
internal DIN alarm. The alarm is activated as long as these contacts are shorted.
The alarm volume can be adjusted by the DIN ALARM CONTROL (29)
By shorting the contacts 4T CHIME START and GROUND the internal 4-tone chime
will be triggered.
The chime volume can be adjusted by the CHIME VOLUME control (28).
During an alarm, chime or announcement via paging station 24V are available
at the PRIO OUT connector (32). This voltage can be used to control a bypass relay.
The maximum current load is 100mA.