Wire Colour
Function
Connect To
Red
Black
Yellow
Power
Ground
Pattern Selection
+12/24 VDC (Power)
-
12/24 VDC (Ground)
+12/24 VDC (Ground)
A
Single Lamp
- Connect yellow wire from light to the bottom terminal of “Momentary ON-OFF” Toggle Switch
- Connect black wire from light to ground
INSTALLATION MANUAL
E-913 Series LED Warning Lights
NO.
Flash Patterns
SAE
1
2
3
4
5
6
Random Patterns
Steady Light
Single Flash
High Intensity Flash
Double Flash
Triple Flash
SAE (E-913A & E-913W)
SAE (E-913A & E-913W)
SAE (E-913A & E-913W)
7
8
9
10
11
12
Quad Flash
Quint Flash
Quad Flash / High Intensity Flash
Single Flash / Quad Flash
Single Flash / High Intensity Flash
Single / Triple / Quad Flash
SAE (E-913A & E-913W)
SAE (E-913A & E-913W)
SAE (E-913A & E-913W)
B
Two Lamps
- Connect fused wire from power source to “ON-OFF” Switch (
ST100 sold separately
)
- Run power wire from “ON/OFF” Switch to the side terminal of “Momentary ON-OFF” Toggle Switch
(
ST108 sold separately
)
- Connect red wires from lights to the side terminal of “Momentary ON-OFF” Toggle Switch
- The next step depends on how many lamps in a series - see below;
Wiring Instructions
- Connect both yellow wires from lights to the bottom terminal of “Momentary ON-OFF” Toggle Switch
- Connect both black wires from lights to ground
- Tap yellow wire to red wire (Power) for 5 seconds to change patterns (see
Flash Patterns
)
- To return to pattern
NO. 1
, touch yellow wire to red wire (Power) quickly 3 times.
Surface Mount: 2 Holes @ 3 ” centres
For more information, visit our website at: www.unibondlighting.com
Pattern Selection (
12 Flash Patterns
)