1.  Periodically inspect the HydroPower system during use. Ensure hoses are  

properly attached. Inspect system for leaks and proper fit of top cap assembly.  

2.  Take care when working to ensure there is enough slack in waterfed wash pole 

hose. This hose is connected to the top of the unit and excessive tugging may 

cause the system to tip over. 

3.  Drinking water flows into the system’s lower connection port via tap pressure 

and flows upwards through the HydroPower tank. Pure water exits through the 

top connection. When plumbing line pressures fall below 40psi, a reduction in 

flow rates will be noticeable.  

4.  The on/off valve can be used to adjust water flow rates coming out of the 

 

waterfed wash pole brush jets. Excessive flow from the brush head jets can 

cause water splattering from uncleaned glass back onto previously cleaned 

areas, resulting in spotting.

 

System Specifications

 

Model 

HP06T  HP12T/HP12C HP24T/HP24C

 

DI Resin Capacity

 

1 bag - 6.0l/0.21 cu. ft. 

2 bags - 12.0l/0.42 cu. ft. 

3 bags - 24l/0.84 cu. ft.

 

Power

 

Tap Pressure 

Tap Pressure 

Tap Pressure

 

Pump

 

NA 

NA 

NA

 

Working Hose Length

 

100 ft./30m plus 

100 ft./30m plus 

100 ft./30m plus

*All values based on 10 ppm as maximum for pure water quality.

Pure Water Production

*

  Soft 

< 100 ppm  

414 gal / 1,570l  

>

 

830 gal  / 3,140l 

> 1,680 gal  / 6,360l

  Medium 

100 – 250 ppm 

 

124 gal - 414 gal / 

 

299 gal - 830 gal /  

 

647 gal - 1,680 gal / 

 

 

470l - 1,570l 

1,130l - 3,140l 

2,450l - 6,360l 

  Hard 

250 – 400 ppm 

 

69 gal - 124 gal / 

 

177 gal - 299 gal /  

 

394 gal - 647 gal / 

 

 

260l - 470l 

670l - 1,130l 

1,490l - 2,450l

  Very Hard 

>

 

400 ppm 

<

 

69 gal / 260l 

<

 

177 gal / 670l 

<

 

394 gal / 1,490l

  Water 

TDS Reading  

HP06 

HP12 

HP24

OUTPUT

Содержание nLite HydroPower HP12 Series

Страница 1: ...ungerglobal com Installation Operating Instructions HP24 Series HP12 Series HP06 Series ...

Страница 2: ...inking water Before servicing system Shut off drinking water supply and open water output Disconnect water supply and allow tank to drain DANGER Spilled resin is a slipping hazard Clean up spilled resin immediately Resin can cause skin irritation Avoid skin contact Wash hands thoroughly after use Can cause eye irritation Avoid eye contact Wear safety goggles In case of eye contact immediately flus...

Страница 3: ...or chemicals Run off does not have to be remediated and is safe for plants and animals No electricity or external power supply needed system works with plumbing line pressure QuickChangeTM resin bags are factory filled with the precise amount of mixed bed DI Resin for optimum system performance As with any commercial equipment care must be taken when operating and servicing the unit There is a ris...

Страница 4: ...s Ensure work area has sufficient water drainage Turn off feed water supply when not in use Transportation Ensure unit is properly secured to car trailer van or truck bed during transportation Intended Use This device may be dangerous if it is improperly installed not regularly maintained or not used as intended Use this device only for water treatment to reach an optimal water quality for glass a...

Страница 5: ... from falling poles caused by incorrect handling or failure of pole Injury through incorrect manual handling of poles and other equipment Hazards from carrying tanks systems and equipment that are overloaded unstable unsecured or incorrectly installed within a vehicle Purified water is delivered to the waterfed wash pole by flexible hose This introduces a risk of tripping by both worker and genera...

Страница 6: ...ting Instructions 6 System Overview FastLockTM Lever Hose Quick Connect FloWaterTM Unit On Off Valve TDS Meter Output Valve Housing with Rugged Outside Appearance QuickChangeTM Resin Bag Packed inside unit Inlet Connection Output Valve ...

Страница 7: ...an drinking water line pressure which typically ranges from 40 to 60 psi This enables the system to produce pure water at up to 1 5 gallons per minute The production of pure water is not sensitive to water temperatures Unger recommends testing the water supply TDS before working see page 12 for more information Mixed bed ion exchange resin eventually becomes exhausted and no longer able to remove ...

Страница 8: ...onversion kits are commonly available so that feed water and waterfed wash pole tubing can be connected ungerglobal com Installation Operating Instructions 8 Standard DI Filter nLite HydroPower Filter System UP TO 30 MORE PURE WATER Tap water goes in FloWaterTM Technology disburses water through resin System Overview continued FloWaterTM Technology The revolutionary Unger FloWaterTM Technology dis...

Страница 9: ...tems that should be shipped with the system then test system for functionality a TDS Meter powers on off b FastLockTM Opening Lever yellow Depress lever rotate in a counterclockwise direction and remove top cap assembly see page 11 for more details c Resin Bag s installed in unit i HP06T series One Bag ii HP12C T series Two Bags iii HP24C T series Four Bags d Quick Connect fittings installed on un...

Страница 10: ...f valves are in OPEN position when filling system CONNECT WATER SUPPLY GARDEN HOSE TO INLET CONNECTION Thread On Off Valve to garden hose prior to connecting water supply Attach On Off Valve directly onto inlet connection at base of unit TURN ON FEED WATER SUPPLY When water begins to flow out of the unit turn on TDS meter and inspect pure water quality A reading of 0 is best and indicates the syst...

Страница 11: ... to OFF position Disconnect waterfed wash pole hose RELEASE SYSTEM HEAD ASSEMBLY While continuing to depress the yellow lever use a counterclockwise quarter turn to release system head assembly remove and set aside Reach into housing and remove exhausted resin by hand discard according to local regulations REPLACE RESIN Drop in new resin bag s by hand be sure to seat bags with zip tie facing up Pa...

Страница 12: ...tes coming out of the waterfed wash pole brush jets Excessive flow from the brush head jets can cause water splattering from uncleaned glass back onto previously cleaned areas resulting in spotting System Specifications Model HP06T HP12T HP12C HP24T HP24C DI Resin Capacity 1 bag 6 0l 0 21 cu ft 2 bags 12 0l 0 42 cu ft 3 bags 24l 0 84 cu ft Power Tap Pressure Tap Pressure Tap Pressure Pump NA NA NA...

Страница 13: ...Hose Quick Connect Outlet Quick Connect adapter garden hose 18481 Inlet Quick Connect Inlet 3 4 BSPT male Quick Connect 19034 Outlet with O Ring Outlet female Quick Connect 18641 Top Cap Assembly Complete w all accessories DITCP FloWater Unit Red distribution plate DIPRE Casters for Tank 4 wheels for direct fix to unit s base DILW2 HydroPower Cart Transportation Cart DICRT TDS Upgrade Kit TDS mete...

Страница 14: ...______________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _________________________...

Страница 15: ..._ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ ______...

Страница 16: ...Unger Enterprises LLC 425 Asylum Street Bridgeport CT 06610 Tel 800 431 2324 Fax 800 367 1988 unger ungerglobal com ungerglobal com Literature 18484 Updated 5 15 ...

Отзывы: