HydroPower® RO35C
Commissioning
4.4.1.
Commissioning of new or preserved RO35C:
The resin filter is not used in new or preserved units, as it must not come into contact with the
diaphragm care agent.
Before using the resin filter, the membrane maintenance agent must be completely rinsed out.
1. Start the appliance as described on page 18 and let it rinse out the
membrane care agent for about 20 minutes.
2. Switch off the RO35C: turn the yellow switch to RO FLUSH.
3. Then turn off the main switch.
4. Disconnect the water supply.
5. Insert the resin cartridge. Make sure that the orientation is correct, the
arrow on the cartridge must point downwards, or the blue paper filter
must point upwards!
6. Press the resin cartridge a little firmly so that it sits well on the rubber
seal.
7. Screw the cover back on.
8. Start the RO35C with steps 1-6 on page 18.
3
The HydroPower RO is now ready for use.
NOTE
You can adjust the amount of pure water produced by moving the yellow control
knob between the left and upper position.
Middle position = Recommended working position, for optimum membrane life.
Below the middle position = Less pure water is produced.
Above the middle position = More pure water is produced. The load on
membranes and resin increases more, which results in higher consumption
costs.