background image

Quality Tools for Smart Cleaning

 

 

www.ungerglobal.com

www.ungerglobal.com

1

OPERATING INSTRUCTIONS

READ THE OPERATING 

INSTRUCTIONS BEFORE SWITCHING 

ON THE SYSTEM!

KEEP IT IN THE IMMEDIATE VICINITY 

OF THE MACHINE AT ALL TIMES!

 

Original operating instructions 

Revision Status: Version 1.1

Unger Germany GmbH 

Piepersberg 44 • 42653 Solingen • Germany

Tel.: +49 (0) 212 2207-0 • Fax: +49 (0) 212 2207-222

E-Mail: [email protected] • www.ungerglobal.com

ENGLISH

Содержание Hydro Power RO System RO40C

Страница 1: ...FORE SWITCHING ON THE SYSTEM KEEP IT IN THE IMMEDIATE VICINITY OF THE MACHINE AT ALL TIMES Original operating instructions Revision Status Version 1 1 Unger Germany GmbH Piepersberg 44 42653 Solingen...

Страница 2: ...tact addresses 9 2 About HydroPower RO 10 2 1 Using the HydroPower RO 10 2 1 1 Intended use 10 2 1 2 Foreseeable misuse 10 2 2 Technical specifications 10 2 2 1 Operating conditions 10 2 2 2 Electrica...

Страница 3: ...rk 23 5 7 Switching off the HydroPower RO 24 5 8 Software update 25 6 Faults and messages 25 6 1 Procedure for accidents 25 6 2 Procedure for malfunctions 26 6 3 Troubleshooting 27 7 Maintenance and s...

Страница 4: ...as the word image mark are legally protected Any duplication processing distribution or transfer to third parties including but not limited to any kind of exploitation outside of the copyright limits...

Страница 5: ...hese rights are owned by third parties Unger Germany GmbH has the corresponding rights of use The software contains business secrets and copyrights No warranty will be given for software that has been...

Страница 6: ...llowing hazard classes are used DANGER Indicates a hazardous situation that can lead to serious injury or death Here you will find measures to avoid the danger CAUTION Indicates a potentially hazardou...

Страница 7: ...igns Warning of a hazard Warning of electrical voltage Warning of overpressure in containers Warning of hot surfaces Warning of suspended loads Warning of injury to the limbs 1 4 5 Mandatory signs App...

Страница 8: ...have been trained in the handling of the HydroPower RO have read and understood the safety instructions and safety regulations in this manual The operator is obligated to ensure that all warnings on...

Страница 9: ...nity of the HydroPower RO and must be available to the entire staff at all times The operator must inform the personnel about the location of these operating instructions If the user manual has become...

Страница 10: ...use is considered to be non compliant and thus unlawful This applies in particular to the use of the HydroPower RO for bacteria removal 2 2 Technical specifications 2 2 1 Operating conditions Ambient...

Страница 11: ...8 GB 2 2 7 Water quality Max salt content in incoming water ppm 1000 SiO2 content in incoming water mg l 20 2 2 8 Water output quantity Pic 1 Dependency of water temperature and hose diameter or numbe...

Страница 12: ...igns Carry out cleaning and maintenance work on the HydroPower RO only if it is disconnected from electricity Turn off the main power switch and unplug the power cord Carry out maintenance on the filt...

Страница 13: ...e parts Before each use perform a visual inspection of the power cable for damage If you notice any damage contact your distributor Maintenance on the electrical components of the system may only be c...

Страница 14: ...act with eyes remove contact lenses and rinse immediately with plenty of water Wash hands after finishing work Use protective gloves and goggles Irreversible injury due to slipping If resin is spilled...

Страница 15: ...1 15 USB connector 16 Concentrate output 17 Power cord 18 Pressure valve with lever for manual draining of water 10 11 12 13 14 1 2 3 4 5 6 7 9 8 15 16 17 18 Interfaces On the front are 3 connections...

Страница 16: ...on behalf of your dealer Complaints due to transport damage cannot be accepted without written confirmation by the dealer or with unreserved acceptance In the case of transport of the HydroPower RO fo...

Страница 17: ...embranes which removes the last 2 of the minerals from the water in the HydroPower RO Pure water is discharged from the 3 water outlets item 5 into a hose connected to a water fed pole for cleaning gl...

Страница 18: ...follows 1 Connect the power cord to the power supply 2 Turn on the main power switch The start screen appears A sequence of images appears in the display which reminds you to connect the hoses and bl...

Страница 19: ...formance is no longer guaranteed 9 The display shows the overview of the resin filter which informs you about the water quality being produced by the HydroPower RO Use the buttons next to the display...

Страница 20: ...in higher consumption costs 5 Operation of the HydroPower RO 5 1 General information Working with the HydroPower RO is only permitted if the operating instructions have been read and understood DANGE...

Страница 21: ...setting menu 5 3 The manometer The manometer shows the water pressure on the membranes when the pump is running Ensure that the water pressure is at least 1 bar The optimum is 4 bar maximum should not...

Страница 22: ...ormation about the performance of the HydroPower RO VOLUME water flow and water production AVERAGES average water values as well as average pure water quality after filtering through the membrane FILT...

Страница 23: ...more water from the membranes than the middle or the left Therefore long hoses or higher poles should be connected to the right water output NOTE The longer the hose from the water outlet to the wate...

Страница 24: ...2 and is discharged through the concentrate hose at the rear To switch off the HydroPower RO after finishing the work proceed as follows 1 Turn the on off knob to the red position The automatic self...

Страница 25: ...brief beep will complete the operation after a few seconds and then you can release the ENTER button 3 3 The HydroPower RO starts normally similar to after switching on 3 3 You can check the correct i...

Страница 26: ...to restart the system Overheating Always ensure that the HydroPower RO is well ventilated and not too close to objects or walls that prevent air circulation 1 If the pump motor overheats the HydroPowe...

Страница 27: ...o check the water pressure of the line proceed as follows 1 Stop the HydroPower RO by pressing the STOP button The manometer indicates the line pressure As soon as the pump is switched on the pressure...

Страница 28: ...ces possible The housing of the pump motor can become hot during operation Allow the system to cool down sufficiently before touching components marked with this symbol Wear protective gloves ATTENTIO...

Страница 29: ...ilter 7 2 1 Daily inspection Observe the indications on the display and the light signals on the 4 selection buttons next to the display and if necessary follow the instructions being shown by the sys...

Страница 30: ...es to rinse the membranes To protect the membrane proceed as follows 1 Switch off the HydroPower RO and disconnect the power supply 2 Drain the water from the HydroPower RO Unscrew all filter top caps...

Страница 31: ...ith the resin when working on the filter cartridges Wear protective gloves and goggles In case of contact with eyes remove contact lenses and rinse immediately with plenty of water Wash hands after fi...

Страница 32: ...he same for all other filter cartridges 3 3 The filter cartridges are replaced NOTE The covers are marked with different shades of blue The dark blue belongs to the front left vessel for the carbon se...

Страница 33: ...n the electrical components of the system may only be carried out by employees of Unger Germany GmbH or their authorized specialist dealers technicians CAUTION Burns due to hot surfaces possible The h...

Страница 34: ...tection 3 3 The HydroPower RO is prepared for storage 8 2 Recycling Properly recycle all materials that can be recycled to help protect our environment The packaging material is to be separated It con...

Страница 35: ...ater inlet and outlet It also indicates the average efficiency of the RO membranes This gives you an overview of the water quality in the region in which you work Under the menu item FILTER CHANGES yo...

Страница 36: ...risk assessment and risk reduction EN 60204 1 2010 Electrical equipment of machines General requirements This is confirmed by the EC Declaration of Conformity Unger Germany GmbH NOTE The system is onl...

Отзывы: