background image

ments set out in this manual) can cause 

harm to people, animals or property. In 

such cases Ungaro is absolved from any 

civil or criminal responsibility;

• Hopper lid must be easily accessible to 

fill the pellets;

• Do not block or reduce the primary air 

inlet, as this is essential for correct com-

bustion;

• Check the chimney for obstructions be-

fore lighting the appliance;

• The safety or control devices must not 

be modified without the specific autho-

risation of the manufacturer. Failure to 

heed this warning will void the warranty, 

with the manufacturer declining all rela-

ted liability;

• The appliance is designed to operate in 

any climatic conditions, as long as it is 

not exposed directly to the weather. In 

the event of particularly harsh conditions 

(strong winds, frost,...), safety devices 

may be activated to switch the heater 

off. Should this occur, contact technical 

service and under no circumstances di-

sable the safety devices;

• The appliance is not intended to be used 

by people of diminished physical, sen-

sorial and mental capacity, including 

children, or people with insufficient ex-

perience or knowledge;

•  Children must be supervised to ensure 

they do not play with the appliance;

• Do not remove the protective grille from 

the pellet hopper; 

• The appliance must not be used as an 

incinerator;

• Do not open the boiler door during its 

operation;

• The thermostove/boiler must not be 

used as a cooking appliance.

2.1 Electrical Safety

The appliance must be connected 

to an electrical system which is 

equipped with an earth conductor, 

as laid down in directives 73/23 

EEC and 93/98 EEC.

• Make sure the power plug is accessible 

after installation of the appliance;

• The power cable must not be in contact 

with hot parts;

• Do not pull, twist or disconnect the elec-

tric cables of the boiler/thermostove 

even if power supply is disconnected;

• Do not wash the appliance with water. 

The water could get inside the unit and 

damage the electrical insulation and 

cause electric shocks;

• Variations in power supply voltage in 

excess of 10% of the rated value may 

affect the correct operation of the ap-

pliance and can lead to serious faults 

within boiler electrical system.Use unin-

terruptible power supply with  frequency  

50Hz and pure sine wave or  pseudo sine 

wave;

• In case of alarm don’t shut the appliance 

down, turn it off only if signal “off” appe-

ars on the display.

The appliance must be connected 

to an electrical system which is 

equipped with an earth conductor, 

as laid down in directives 73/23 

EEC and 93/98 EEC.

2.2 Operating Warnings

• During  the  first  two  or  three  ignitions 

vent the room several times;

• Pellets must not be fed manually into the 

burning pot;

• Filling the hopper with pellet make sure 

that the plastic bag doesn’t come into 

contact with the hot surfaces;

• Un-burnt pellets accumulated in the 

burning pot must be removed before re-

lighting. Not observing this may cause 

detonation in the combustion chamber 

with harm to people, animals or proper-

ty;

• Do not touch the boiler/thermostove 

with wet hands or bare feet in view of 

the fact that it is an electrical appliance;

• Avoid coming into contact with the hot 

parts of the appliance; 

• Do not stand for a long time in front of 

the hot air vent (if the model has forced 

hot air);

• Do not expose plants or animals directly 

to the hot air flow;

• Do not light the appliance with flamma-

ble materials. If the ignition system bre-

aks down, please contact the Technical 

Support in your area. 

Содержание FIT C 4-15

Страница 1: ...luenth2 0 F INSTALLATION AND OPERATION MANUAL...

Страница 2: ...y and sustainability of each model according to the most stringent European standards regulating emissions and safety In order to get the best performance please read carefully this manual before usin...

Страница 3: ...uality of pellets used Please use pellets that meet requirements of the standard ISO 17225 2 class A1 To ensure good combustion pellets must be stored in an area that is free of humi dity ATTENTION Th...

Страница 4: ...ible after installation of the appliance The power cable must not be in contact with hot parts Do not pull twist or disconnect the elec tric cables of the boiler thermostove even if power supply is di...

Страница 5: ...n Heating system booklet Documentation for the installation The technical documentation includes Reference to the current standards Manufacturers installation indications A rough description or scheme...

Страница 6: ...e length is 3 meters with an upward slope of 3 Flue gasses discharge on the wall is not permitted by current regulations Failure to comply can lead to the ter mination of the guarantee and of the manu...

Страница 7: ...section fig 5 Existing Flue Models Yncas fig 6 These models need careful planning at an early stage of the installation process Po sition the appliance bearing in mind all the instructions and conside...

Страница 8: ...tem Compliance Certificate must be issued under the responsi bility of the installer Please follow up local regulations and directives es regional building regulations requirements for hea ting device...

Страница 9: ...sheme on fig 11 the generator is connected to an external vessel The mo therboard manages both the boiler and the buffer Set the temperature required in the buffer tank The boiler heats the water in...

Страница 10: ...in Check Up phase Cleaning A careful cleaning of the hea ter is necessary Appears au tomatically after some hours of work Block state name The message appears if the appliance was shut down not manual...

Страница 11: ...oiler With the climatic function enabled the value can t be modified manually it s regulated by the heater according to the outside temperature Buffer tank The menu is for setting the temperature in t...

Страница 12: ...day Friday Mon Fri Sat Sun Night Mode In this menu can be set the time slot for Night Mode the reduced operation mode The programming is similar to the one described in the Chrono Mode To program the...

Страница 13: ...Enabled ON OFF Boiler thermostat set manually Comfort is available only with the Climatic function enabled It gives the possibility to modify the ther mostat temperature in the range 20 C The Comfort...

Страница 14: ...ode Once the automatic power is enabled all the menus of the combustion settings will no longer be visible Loading the menu is for autimatic pellet loading It will stops automatically after 300 second...

Страница 15: ...tion Illustrate how to turn on and off theap pliance and adjust water temperature through the User Menu Demonstrate where and how to fill the ap pliance with fuel and advise of the correct quality of...

Страница 16: ...installed set the domestic hot water temperature in the submenu Buffer tank Completed the settings press and hold the ON button to start 6 3 Ignition Press and hold the power botton until the signal...

Страница 17: ...s intervention 7 4 Exchanger Manual Cleaning Remove the butterfly screw pull and push intensively several times the grate of exchanger cleaner fig 19 This operation should be performed each three days...

Страница 18: ...eline cleaning Exhaust fan base cleaning Motherboard cleaning Floor protection cleaning Hot air tangential fan cleaning Ignition resistance Burning pot s integrity Gearmotor integrity Expansion vessel...

Страница 19: ...p is blocked Shut off valves are closed If domestic hot water kit is installed and the display shows false hot water re quest contact Technical Support The temperature in the hopper is too high To tur...

Страница 20: ...pection compartment where the exhaust fan is situated Inspect the chimney Er07 Er08 Incorrect operation of exhaust fan or control panel Contact Customer Support in your area Er09 Low water pression Co...

Страница 21: ...e Only authorized Ungaro personnel may ac cess to the electrical or mecanical parts of the appliance Contact your retail shop with questions regarding installation operation or service 10 1 Technical...

Страница 22: ...3 Documents to ask to Authorized Technician At the end of intervention the technician will give 1 Service Log signed 2 Invoice for the used spare parts for out of warranty interventions fig 24 Serial...

Страница 23: ...19 3 23 1 Min kW 6 5 8 6 5 8 3 6 2 4 9 6 5 4 4 6 6 Efficiency P Max 91 5 90 90 5 90 5 93 91 8 91 5 91 2 92 5 93 P Min 94 95 5 95 5 95 95 1 96 6 94 90 6 90 6 93 Power to water P Max kW 19 5 24 19 5 28...

Страница 24: ...A1 4 15 4 20 4 25 kW 580 60 entrata aria ritorno impianto 3 4 1300 calda sanitaria 1 2 fredda sanitaria 1 2 560 80 100 uscita fumi 104 259 322 5 197 8 64 8 64 8 115 99 2 mandata impianto 3 4 valvola...

Страница 25: ...s Classic FIT CS X 4 15 4 20 4 25 kW 139 110 5 183 151 865 1220 28 280 483 4 82 1 418 5 43 451 9 138 5 322 5 475 5 65 115 65 134 7 AQA F CS 4 15 4 20 4 25 kW AQA F Plus 6 24 kw MAIA F PLUS 6 24 kW A B...

Страница 26: ...fumi 581 1120 1206 5 104 65 65 115 99 110 198 169 259 257 148 322 5 AQA X 6 24 8 30 kW 60 Entrata aria 80 Uscita fumi 3 4 Mandata impianto 1 2 Calda sanitaria 1 2 Fredda sanitaria 3 4 Ritorno impianto...

Страница 27: ...30 620 600 1120 A B C D 144 349 153 129 148 275 163 Fit I 6 24 kW Uscita fumi 100 Uscita fumi 100 Entrata aria 60 82 82 80 Smoke Exhaust 60 Air inlet 3 4 Heating Flow 3 4 Heating return 100 Smoke Exh...

Страница 28: ...28 YNCAS L 6 24 kW 871 5 758 899 776 135 81 100 caduta pellet 100 uscita fumi 326 182 5 60 entrata aria 43 250 100 145 280 620 620 100 Smoke Exhaust 100 Pellet hopper 60 Air inlet...

Страница 29: ...29 INSTALLATION AND OPERATION MANUAL Kucina 5 20 600 890 950 110 170 604 97 5 65 115 65 147 208 C E F D 600 605 9 86 120 A B...

Страница 30: ...c glass painted fini shes and other external finishes The Customer is in charge of eventual costs re pair transport arising from improper exercise of warranty rights Ungaro S r l is not responsible fo...

Страница 31: ...uch data available to a data processor under the terms and conditions set out by the Personal Data Protection Act I acknowledge my right to access the personal data edit it and to withdraw this consen...

Страница 32: ...0 SAN MANGO D AQUINO CZ Italy Tel 39 0968 926838 Tel 39 0968 96484 Fax 39 0968 926635 www caldoungaro it Under no circumstances shall Ungaro S r l assume liability for imprecise contents or eventual e...

Отзывы: