9. Before installation, remove all silicone gaskets (if present) from the joints of the pellet pipe, and dispose of
the gaskets appropriately. All joints must be secured with at least 3 self-tapping screws per joint.
!
10.
CANADA:
No chimney connector shall pass through an attic or roof space, closet, or similar concealed
space, or a floor, or ceiling. Where passage through a wall, or partition of combustible construction is
desired, the installation shall conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances
and Equipment.
!
11. CAUTION: WHEN VENTING WITH THIS APPROVED CHIMNEY SYSTEM, FOLLOW
ONLY
THESE
INSTALLATION INSTRUCTIONS FOR CONNECTING THE KIMBERLY™ WOOD STOVE HEATER.
!
12.CAUTION:
NEVER
FOLLOW INSTALLATION INSTRUCTIONS OR CLEARANCE RECOMMENDATIONS
WHICH MAY BE PROVIDED BY ANY PELLET PIPE MANUFACTURER.
!
13.CAUTION: BEFORE INSTALLATION, REMOVE ALL SILICONE GASKETS FROM THE JOINTS OF ANY
PELLET PIPE (IF PRESENT) AND DISPOSE OF THE GASKETS APPROPRIATELY.
!
14.CAUTION:
DO NOT
USE A REDUCER TO JOIN THE 3-INCH PELLET PIPE WITH THE 6-INCH CLASS-A
PIPE. NOTE: THE 3-INCH PELLET PIPE WILL CARRY THE FLUE GASES FROM THE STOVE TO THE
TOP OF THE CHIMNEY. THE 6-INCH CLASS-A PIPE IS USED AS A CONDUIT FOR THE 3-INCH PELLET
PIPE. THE 3-INCH PELLET PIPE SHOULD TERMINATE
FLUSH
WITH THE 6-INCH CLASS-A PIPE OR
TERMINATE A FEW INCHES
ABOVE
THE 6-INCH CLASS-A PIPE. THE 3-INCH PELLET PIPE SHOULD
NEVER
TERMINATE BELOW THE 6-INCH CLASS-A PIPE.
!
15.CAUTION: NEVER UTILIZE MAKE-SHIFT COMPROMISES DURING INSTALLATION. NEVER INSTALL
ANY WOOD STOVE OR CHIMNEY SYSTEMS OUTSIDE OF THE PROVISIONS OUTLINED IN THE
NFPA-211 SAFETY STANDARDS (OR CANADIAN EQUIVALENT).
!
ADDITIONAL REQUIREMENTS FOR MOBILE HOME INSTALLATIONS IN THE U.S.A.
!
1. The Kimberly™ wood stove heater must be bolted to the mobile home chassis, using the three pre-drilled
holes at the base of the Kimberly™ wood stove heater, and three 1/2-inch hex-head bolts of 1/4-inch
diameter and 2-1/2 inches long (or the metric equivalent) which may be purchased at a hardware store.
!
2. All U.S.A. mobile home installations require an outside air kit (OAKP or OAKL) to provide the Kimberly™
wood stove heater with a supply of outside combustion air. The Kimberly™ wood stove heater has a 2-inch
(5.1 cm) air inlet under the base of the stove to accommodate such a kit. The Kimberly™ wood stove heater
may include an additional air inlet at the back of the stove. Use one outside combustion air inlet or the other,
but not both.
!
3. Choose a location for the outside air inlet that will not interfere with bolting the Kimberly™ wood stove heater
to the mobile home chassis. To discourage entry by insects and rodents, the outside air inlet should be
protected by a fine mesh screen on the external end.
!
4.
U.S.A.
: All mobile home installations require that the Kimberly™ wood stove heater must be electrically
grounded to the chassis, and the chimney must include a spark arrester cap.
!
5.
CANADA
: The Kimberly™ wood stove heater is
not
approved for mobile home use in Canada.
!
6. CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF
MUST BE MAINTAINED.
!
7. CAUTION: USE ALL INSTALLATION COMPONENTS AS SPECIFIED IN THIS MANUAL. NEVER OMIT ANY
PARTS OR SUBSTITUTE WITH OTHER COMPONENTS.
!
8. CAUTION: THE INTEGRITY OF ANY VAPOR BARRIERS MUST BE MAINTAINED.
!
9. CAUTION: DO NOT INSTALL IN SLEEPING ROOM.
!
www.UnforgettableFireLLC.com
6
Kimberly™ Owner’s Manual
Содержание Katydid
Страница 1: ...K i mb e r l y Wo o dS t o v e U n f o r g e t t a b l eF i r e ...
Страница 23: ...D i a g r a m 1 D i a g r a m 2 ...
Страница 25: ...D i a g r a m 5 D i a g r a m 6 F l o o r P r o t e c t o r ...
Страница 26: ...D i a g r a m 7 4 5 7 2 ...
Страница 29: ...D i a g r a m 1 2 ...