Table 7: Dimensions and weight
Model
Length (mm)
*1
Width (mm)
*1
Height (mm)
*1
Weight (kg)
*2
RSU-352
220.5
127.5
72.3
2.7
Note:
*1: Enclosure only without any accessory, antenna ports excluded.
*2: With all accessories: V2X antennas, GNSS antenna, surge protector, mounting bracket, and earth
wire.
11.
Software Settings
The following BSP settings are applicable for Unex software package only.
Table 8: Unex BSP interface settings
Function
Description
Ethernet
Default IP address 192.168.100.3
GNSS NMEA
UART1, 230400bps, 8N1, ttyAMA1
GNSS Reset
GPIO111, 0->1 = GNSS module reset (cold start, clear SRAM
and RTC)
mPCIe Reset
GPIO 511, 0->1 = mPCIe module reset
STATUS LED Green
/sys/class/leds/status-green/brightness, 0=OFF, 1-255=ON
STATUS LED Red
/sys/class/leds/status-red/brightness, 0=OFF, 1-255=ON
V2X0 antenna detection /sys/bus/iio/devices/iio\:device0/in_voltage4_raw
V2X1 antenna detection /sys/bus/iio/devices/iio\:device0/in_voltage5_raw
MAC address
grep V2X_0 /etc/unex/device/device_info.txt
BSP/protocol version
/etc/unex/update.log