If the radar installation environment is for water object detection, radar install at
bridge to monitoring ships on the surface of water, like figure 2-9.
● The radar is mounted horizontally on the bridge and is installed in a bridge/wa-
ter center position.
● The radar normal are facing forward and the installation angle not to be tilted
down.
⑤
If the radar installation environment is for water object detection, radar install at
shore to monitoring ships on the surface of water, like figure 2-10.
● The radar is mounted horizontally on a pole, which is less than 6 meters height.
● The radar normal are water center and the installation angle not to be tilted
down.
⑥
Fig.2-7
Fig.2-8
If the radar installation environment is for fence perimeter protection, and to
monitoring the fence outside targets against intrusion.like figure 2-7.
● The radar is mounted on the outside of the fence, close to or directly above the
fence (for best performance).
● The radar installation height is recommended to be 2 meters, which can be
adjusted according to actual needs but not to exceed 6m.
Radar detection blind area is different for different installation heights, generally
radar installation height no more than 3m or 4m is recommended; If the radar is
installed directly above the fence, it is recommended that the radar installation
height be between 0.5 and 1 meters directly above the fence.
The camera installation height be 3 to 6 meters.
● To Monitoring the outside area of the fence, the horizontal angle of the radar
installation should inclines to the outside of the fence by 30°.
If the area inside the fence also needs to be monitored, the radar can be adjusted
back to the inside of the fence at an appropriate horizontal angle as required.
③
If the radar installation environment is for fence perimeter protection, and to
monitoring the fence inside targets against intrusion.like figure 2-8.
● The radar is mounted on the inside of the fence, close to or directly above the
fence (for best performance).
● The radar installation height is recommended to be 2 meters, which can be
adjusted according to actual needs but not to exceed 6m.
Radar detection blind area is different for different installation heights, generally
radar installation height no more than 3m or 4m is recommended; If the radar is
installed directly above the fence, it is recommended that the radar installation
height be between 0.5 and 1 meters directly above the fence.
The camera installation height be 3 to 6 meters.
● To Monitoring the inside area of the fence, the horizontal angle of the radar
installation should inclines to the inside of the fence by 30°.
If the area outside the fence also needs to be monitored, the radar can be adjusted
back to the outside of the fence at an appropriate horizontal angle as required.
④
2.5 Bootup Description
Please refer to the Installation Guide to use the radar, connect the cable well accord
-
ing to port definition after completing installation. The radar will generate brief signal
of the di sound fourth after powering on the system, which means the system is
normally launched. Then you can read the protocol data from the Ethernet port.
Device Wiring and Connection
3.1 Device Wiring
Note:
●
The following figure which shows the device installation is for reference only.
Please refer to the actual device wiring instruction for more details.
●
Please refer to below operation if network waterproof connector need to be
installed(optional)
Waterproof network connector(optional) is shown as Fig. 3-1
3.
Millimeter Wave Radar
Millimeter Wave Radar
6
● ●
5
●
●
Monitoring outside area of the fence to prevent intrusion
Monitoring inside area of the fence to prevent intrusion
Fig.
2-9
Fig.
2-10
Radar
Radar
Bridge
Radar normal
Radar normal
Water surface
Water surface
Содержание SN-SMWR02A