If the radar installation environment is for water object detection, radar install at 
bridge to monitoring ships on the surface of water, like figure 2-9.
● The radar is mounted horizontally on the bridge and is installed in a bridge/wa-

ter center position.

● The radar normal are facing forward and the installation angle not to be tilted

down.

 If the radar installation environment is for water object detection, radar install at 
shore to monitoring ships on the surface of water, like figure 2-10.
● The radar is mounted horizontally on a pole, which is less than 6 meters height.
● The radar normal are water center and the installation angle not to be tilted

down.

Fig.2-7

Fig.2-8

 If the radar installation environment is for fence perimeter protection, and to 

monitoring the fence outside targets against intrusion.like figure 2-7.
● The radar is mounted on the outside of the fence, close to or directly above the
fence (for best performance).
● The  radar  installation  height  is  recommended  to  be  2  meters,  which  can  be
adjusted according to actual needs but not to exceed 6m. 

Radar detection blind area is different for different installation heights, generally

radar installation height no more than 3m or 4m is recommended; If the radar is

installed directly above the fence, it is recommended that the radar installation

height be between 0.5 and 1 meters directly above the fence.
The camera installation height be 3 to 6 meters.
● To Monitoring the outside area of the fence, the horizontal angle of the radar
installation should inclines to the outside of the fence by 30°.
If the area inside the fence also needs to be monitored, the radar can be adjusted
back to the inside of the fence at an appropriate horizontal angle as required. 

If the radar installation environment is for fence perimeter protection, and to 

monitoring the fence inside targets against intrusion.like figure 2-8.
● The radar is mounted on the inside of the fence, close to or directly above the
fence (for best performance).
● The  radar  installation  height  is  recommended  to  be  2  meters,  which  can  be
adjusted according to actual needs but not to exceed 6m. 

Radar detection blind area is different for different installation heights, generally

radar installation height no more than 3m or 4m is recommended; If the radar is

installed directly above the fence, it is recommended that the radar installation

height be between 0.5 and 1 meters directly above the fence.
The camera installation height be 3 to 6 meters.
● To Monitoring the inside area of the fence, the horizontal angle of the radar
installation should inclines to the inside of the fence by 30°.
If the area outside the fence also needs to be monitored, the radar can be adjusted
back to the outside of the fence at an appropriate horizontal angle as required.

2.5  Bootup Description

Please refer to the Installation Guide to use the radar, connect the cable well accord

-

ing to port definition after completing installation. The radar will generate brief signal 
of the di sound fourth after powering on the system, which means the system is 

normally launched. Then you can read the protocol data from the Ethernet port.

Device Wiring and Connection

3.1  Device Wiring

Note:

The following figure which shows the device installation is for reference only.

Please refer to the actual device wiring instruction for more details.

Please refer to below operation if network waterproof connector need to be

installed(optional)
Waterproof network connector(optional) is shown as Fig. 3-1

3.

Millimeter Wave Radar

Millimeter Wave Radar

6

●                                 ●

5

                   ●

Monitoring outside area of the fence to prevent intrusion

Monitoring inside area of the fence to prevent intrusion

Fig.

2-9

Fig.

2-10

Radar

Radar

Bridge

Radar normal

Radar normal

Water surface

Water surface

Содержание SN-SMWR02A

Страница 1: ...Millimeter Wave Radar User Manual...

Страница 2: ...ing of the building Prevent the power cable from being trampled or pressed especially the plug power socket and the device adaptor We assumenoliability or responsibility for all the firesor electrical...

Страница 3: ...th to clean the device If the dust is difficult to be removed please wipe it away with a clean cloth wetted slightly by the mild detergent and then use dry cloth to clean the device Do not use volatil...

Страница 4: ...ull load el ectrical durability 100000 times If the tolerance sen sibilityLoad please keep the current allowance in place High and low level input It s the optocoupler drive end which requires driving...

Страница 5: ...enerally the radar antenna plane shall be installed vertical to alert area in order to guarantee the precision of the radar besides it needs to be installed at a certain height which normally is recom...

Страница 6: ...is for fence perimeter protection and to monitoring the fence inside targets against intrusion like figure 2 8 The radar is mounted on the inside of the fence close to or directly above the fence for...

Страница 7: ...ts user manual Installation and configuration of the software shall subject to the user manual Test steps as follows Test equipment required is shown as table 3 1 Table3 1 Connect PC and SMWR02A SMWR0...

Страница 8: ...eckwhethercanpingradar Pleaserefertochapter2 3andcheckifradarinstallationdirectioniscorrect UsedesignatedFMCWsimulatortocheckifradaroutputisnormal Pleasecheckiftheradarinstallationpositionaimsatthetar...

Страница 9: ...of this warranty certificate Replacement due to quality problems within 7 days since the purchase date is available The warranty period is 1 years Priority to access for new product information or pr...

Отзывы: