PLACING A LOAD

Always place a load onto the platform

gently. Sudden shock/excessive force

may cause damage to the weight sensor

inside. It is a good practice to remove

all loads from platform immediately

after weighed. This would prolong the

life time of the weight sensor.

4.7

SELECT BACKLIGHT (option) STATUS

To enable/disable backlight function,

press MODE until the desired status is

attained.

Backlight

would

automatically go off 3 second after zero

weight is detected and automatically

turned on immediately after a load is

detected.

4.8

WEIGHT MEMORY FUNCTION

4.8.1

Save a Weight to Memory and Auto Weight

Accumulation

When weight display is stable, press M+

to save. Scale Displays “

P.1

” and the

M+ arrow appears indicating total number

of total entries and the memory function

is being employed.

4.8.2

Recall Weight Accumulated

Press

MR

, scale displays total number

of entries and total accumulated weight

of these translations. Scale return to

normal operation status 2 seconds after

accumulated weight displayed.

4.8.3

Memory Clear

Press and hold

MR

, then press

TARE

after

accumulated

weight

display.

Scale

displays “

P.0

” and all data is cleared.

4.8.4

CAUTIONS

ALL data stored will be erased if:

the scale is turned off

weight unit is changed

4.9

SELECT AUTO POWER OFF STATUS

This unit is equipped with AUTO POWER

OFF function.

Default setting = auto off after 4 minutes

unused.

Follow the below steps to disable/employ

the AUTO POWER OFF function.

a.

turn scale off

Содержание BM-30

Страница 1: ...REFULLY BEFORE ATTEMPTING TO OPERATE THIS SCALE June 2010 REV 1 Specifications subject to change without prior notice CONTENTS 1 INSTALLATION 2 SPECIFICATIONS 3 KEYBOARD LAYOUT AND DESCRIPTION 4 INSTR...

Страница 2: ...ht position then locked it by the Allen head screw provided 1 2 3 Connect the cable plug to the indicator receiving plug 1 2 3 1After plugs are connected lock the plugs by turning the plug screw in cl...

Страница 3: ...d and pound ounce Operation Environment 0o 40o C 32o 104o F Non condensed R H 85 Specifications subject to change without notice NOTE A To comply with the law of certain countries the avoirdupois weig...

Страница 4: ...cate a zero weight status 9 TARE INDICATOR An arrow will appear and point at this sign when the tare function is being employed 10 M INDICATOR An arrow will appear and point at this sign when the memo...

Страница 5: ...unit a turn scale off b press and hold TARE then press ON OFF Scale displays F 1 c press TARE twice Scale displays F 3 d press and hold MODE e press MODE unit the lb signs appear or select kg to disab...

Страница 6: ...n When weight display is stable press M to save Scale Displays P 1 and the M arrowappearsindicatingtotalnumber of total entries and the memory function is being employed 4 8 2 Recall Weight Accumulate...

Страница 7: ...r at least 8 hours or plug in the mains adapter input CHECK Isthemainadapter ACinputinserted properly both to the wall outlet CHECK Is the outputplugofthemainadapter inserted properly into the DC inle...

Страница 8: ...ll disturbances CHECK Is the scale calibrated correctly ACTION Contact your local dealer CHECK Is part of the load striking against the pillar ACTION Place load properly SYNDROME SCALE TURNED OFF AUTO...

Страница 9: ...f the scale periodically Re calibrate the scale when needed NOTE in some countries calibration is restricted to be done by qualified authorized agent only Contact your local dealer for more informatio...

Отзывы: