INSTALLATION MANUAL HELIOCOL
®
SOLAR POOL HEATER
NOTE:
All four corners of each row of panels should be securely fastened to the roof. The corners should already be
secured with the gator clamps or pipe straps on the plumbing lines connected to the feed and return lines. The top corner
opposite the return corner should already be secured by the panel mounting hardware.
The above photo (left) shows the return line attached to
the top header and an end cap on the bottom header.
The photo insert (center) the return line connection in
detail.
The above photo (right) shows the feed line attached
to the bottom header and an end cap attached to the
top header.
NOTE:
Be sure to support all of the weight of the plumbing with gator clamps or pipe straps. The mounting hardware is
not designed to support the weight of the plumbing in addition to the weight of the collectors.
12. Running the Feed & Return Lines
From Roof to Ground Level.
- Cont.
RUNNING THE FEED & RETURN LINES FROM ROOF TO GROUND LEVEL.
-
21
Fig. 12.1
©
2014 UMA Solar