background image

     

-29-

8. Specifications 

8.1 Specifications

 

Model 

DISL-503 

Back-up material 

Silicon rubber 

Displacement 

50Hz 

433 

L/min 

60Hz 

516 

Ultimate pressure Pa 

30 

Max. inlet pressure 

Atmospheric pressure 

Ambient operating temperature 

 

5~40 

M

ot

or

 

Type 

3-phase squirrel cage induction motor,

 IE3, 

Totally-enclosed, 

2-pole, Thermal class 155(F), Multiplex voltage, IP44 

Output kW 

0.9 / 1.1 (50Hz / 60Hz) 

Voltage V 

200 

220 

230 

380 

400 

415 

460 

Rated current 

50Hz 

3.7 

1.88 

1.87 

1.88 

60Hz 

4.1 

3.9 

3.8 

1.92 

Revolution

 

50Hz 

2920 

2910 

2920 

2920 

min

-1

{rpm}

 

60Hz 

3480 

3500 

3510 

3510 

Noise level 1m dB(A) 
(With air-flush ON) 

64 

(

69) 

Inlet connection 

NW25 [Internal screw size : Rc1/2] 

Outlet connection 

NW25 [With exhaust valve] 

Dimensions mm 
L×W×H 

521×317×280 

Mass kg 

34 

Cooling system 

Air-cooled system with cooling fan 

Others 

With hour counter and air-flush 

Note 1

The model number scheme is defined by material, which is used for back-up of P-seal. 

(Refer to page 10 [Structure of vacuum pump] of the instruction manual ) 

Note 2

Fluorine rubber used in this product may not be compatible for certain chemicals. 

Please contact chemical supplier. 

Note 3

Pumping speed and ultimate pressure should remain the same whether air-flush system is used or not. 

Note 4

Maximum voltage allowance is + or - 10% from motor rating. 

Note 5

Noise level is measured at ultimate pressure in an anechoic room. 

Note 6

Vapor handling volume is no more than 250g/day (at 25

  60%RH) with air-flush opened operation.   

Air-flush flow rate is 10L/min. 

Note 7

This product is wired for 200V at the factory. 

Note 8

For continuous duty with water vapor, install optional exhaust silencer. 

Note 9

This product is not equipped with motor protection device. 

Install branch circuit protection device for safety. Consult to qualified electrician for details. 

Note 10

This product is designed for indoor use. Install the product away from moistures or excessive humidity. 

Note 11

All data shown in this literature were measured based on our test standard and specific conditions.   
Actual measurements are subject to change of conditions of use. 

Note 12

The specification might change without a previous notice for the quality improvement. 

 

 

Содержание DISL-503

Страница 1: ...o sold it to you Purchase date When you began operation This instruction manual includes very important warnings cautions and operating procedure in order to operate this pump safely and efficiently B...

Страница 2: ...ve the following meanings Examples of marks WARNING Indicates a potentially hazardous situation which if not avoided may result in serious injury or loss of life CAUTION Indicates a potentially hazard...

Страница 3: ...protect branch circuit If equipment is not stopped in an emergency it can cause accident fire or failure Install emergency stop switch Danger of accident fire or failure Be sure to install an electric...

Страница 4: ...er Danger of electric shock and entanglement Do not remove or alter safeguards or insulation parts If done it can cause bodily injury from electric shock or turning section and it can cause deteriorat...

Страница 5: ...cord correctly to terminal block Improper wiring and incorrect voltage can cause motor burnout Inspect cause of problem Danger of problem recurrence and failure Ifprotectivedeviceorthermalprotectorac...

Страница 6: ...ware of intake gas volume Danger of exceeding permissible intake gas volume When sending N2 gas or dry air into air flush port pressure should be the same as atmospheric pressure and flow rate should...

Страница 7: ...Where to attach warning stickers Where to attach warning stickers Always keep warning stickers clean and legible If they become dirty or detached replace them with new ones If you need replacement sti...

Страница 8: ...wn 22 4 2 Air flush opened operation 23 4 2 1 Preparation 23 4 2 2 Start up and shut down 24 4 2 3 When returning to air flush closed operation 24 4 3 Water separator silencer Option 25 5 Maintenance...

Страница 9: ...re is no damage If there is any damage contact either our sales branches who sold it to you or local sales offices Check the following accessories Instruction manual this one Air muffler for air flush...

Страница 10: ...kgs while paying attention to stability of suspended load If not it can cause damage failure or bodily injury from falling cargo due to hoisting failure or by being caught between suspended cargo and...

Страница 11: ...Direction Plate Eye Bold Terminal Box Housing Inlet NW25 Internal screw size Rc 1 2 Outlet NW25 Air Flush Port Rc1 8 It is closed by plug when delivered to you FS Cover Hour Counter Motor Fan Cover C...

Страница 12: ...ilated area refer to below chart Poor ventilation can disrupt cooling and cause accident failure or bodily injury such as burns since this vacuum pump is an air cooled type Do not block inlet and outl...

Страница 13: ...se of wiring and connecting Important When building vacuum pump into vacuum system pay attention to space for maintenance ambient temperature and piping Be sure to fix vacuum pump on solid and level f...

Страница 14: ...ct motor If not bodily injury due to electric fire or electric shock can result If you have any questions about the selection of protective devices contact either our sales branches who sold it to you...

Страница 15: ...rding to EN60947 2 and is equipped with an operating handle which is lockable in OFF position and complies with the other requirements of EN60204 1 clause 5 3 CAUTION Motor burnout Before doing any wi...

Страница 16: ...2 1 415 50 2 1 460 60 2 2 Electric Source Terminal M4 Nut Earth Terminal M5 Bolt Cable gland Activate the emergency stop by electric source switch or protective device Avoid motor burnout by protectiv...

Страница 17: ...ble gland at 22mm hole of motor terminal box Insert electric source cable through cable gland on the bottom side of terminal box Connect each phase L1 L2 L3 to each electric source terminal respective...

Страница 18: ...is flowing If not it can cause accident failure or bodily injury such as burns due to overheating Check fan Test operation Open inlet and outlet Remove caps 2 places from inlet and outlet of vacuum pu...

Страница 19: ...ted Important Vacuum pump turns counter clockwise when viewed from motor side Check that air comes out from outlet If air does not come out from outlet stop vacuum pump turn off electrical source and...

Страница 20: ...tart up and shut down We recommend the use of leak valve also We recommend the use of an automatic valve as the isolation valve which closes during power failure in order to prevent the drawback of de...

Страница 21: ...Never evacuate hazardous gas Danger of entanglement and foreign matter dispersal Never put finger or foreign matter into air holes of fan cover FS cover If done it can cause bodily injury from entangl...

Страница 22: ...ible intake gas volume When sending N2 gas or dry air into air flush port pressure should be the same as atmospheric pressure and flow rate should be less than 10L min If not it can increase pressure...

Страница 23: ...ection If not it can cause failure When doing air flush opened operation Noise level will increase by 5dB Install pump in an area which is not exposed to debris such as iron powder stone powder polish...

Страница 24: ...standard differs when evacuating vapor You must shorten maintenance interval 5 2 page 27 when evacuating vapor since vapor temperature disposal volume disposal frequency and substances in vapor have a...

Страница 25: ...valve between vacuum pump and vacuum chamber during pump shut down If vacuum pump stops during air flush opened operation atmospheric air is drawn back from air flush port to inside of vacuum pump an...

Страница 26: ...water separator silencer into the outlet joint Set the water outlet of water separator silencer downwards Put the rubber hose into water outlet and tighten the connection by hose band Be sure to open...

Страница 27: ...specialist to perform repairs Defective repairs can cause accident failure or shorter operating lifetime Ask specialist to perform repairs 5 1 Daily maintenance and inspection Conduct the following da...

Страница 28: ...ace if something goes wrong Note 1 Be sure to use designated DISL exclusive grease Note 2 You must shorten maintenance standard when pumping vapor since vapor temuperature disposal volume disposal fre...

Страница 29: ...r protection gear activates Air outlet is clogged Inspect and repair Ultimate pressure is insufficient Air leaks from piping O ring is damaged Check tightness of piping Replace Moisture and solvent ar...

Страница 30: ...anual Note 2 Fluorine rubber used in this product may not be compatible for certain chemicals Please contact chemical supplier Note 3 Pumping speed and ultimate pressure should remain the same whether...

Страница 31: ...30 8 2 Dimensions 8 3 Performance data 60Hz 50Hz...

Страница 32: ...31 Memo...

Страница 33: ...mp Therefore any damage to the other products caused by a malfunction of this vacuum pump shall not be covered by the warranty This warranty is valid only in Japan 9 2 After sales and service Periodic...

Страница 34: ...ring Trouble situation Unusual sound Pressure degradation Irregular action Others Purpose of the usage Device s name if necessary Evacuated gas Type of the gas Hazardous situations for injury Yes No T...

Отзывы: