© 12/2006 UltraVolt HV Rack System Installation and Operators Manual, Rev A
18 of 23
Reference Voltage A
{B/C/D}: This is a 5VDC precision output reference and can be used as a source voltage
to control the
Remote Voltage Adj A
{B/C/D} and the
Remote Current Adj A
{B/C/D} remote-input
signals.
Signal Ground A
{B/C/D}: This is signal return ground for Channel A {B/C/D}.
In addition to individual channel I/O control and status signals, there is a
Global Disable
signal:
Global Disable
{channels A, B, C, and D}: This is a digital input signal, TTL level, that when asserted True
(+5VDC) disables all high-voltage outputs; when asserted False (0VDC), it enables all high-voltage
outputs.
A +15VDC, 100mA power tap and return is also available on the remote connector. It can be used to power
external circuitry.