SCHEDULED UV LAMP(S) REPLACEMENT
The UV lamps have a useful life of approximately
13,000 hours and should be replaced at that time.
Even though the lamp(s) may be glowing after
13,000 hours of operation they have reached the
end of their useful life.
LAMP REPLACEMENT PROCEDURE
1. Turn off all power to the ULTRA UV2 unit and all
other pool equipment. Unplug the unit from it
s
power receptacle or turn OFF the circuit breake
r
that is the ULTRA UV2’s power source. Befor
e
proceeding to step 2 allow at least 15 minutes fo
r
the lamp(s) in the unit to cool.
Never remove the
electrical enclosure
cover without first
disconnecting the power (power source) for the Ultra
UV2 unit. Never remove the Ultra UV2 unit’s cover
without turning off the pump.
DANGER
2. Remove the three screws that secure the plastic
cover then remove Fig. 1
.
Before removing
lamps you must wea
r
protective rubber
gloves and safety eye wear. Do not handle a hot lamp
or serious burns will occur.
WARNING
Do not touch the
glass part of th
e
lamp as body oils will
create hot spots & greatly shorten lamp life.
NOTICE
3. Disconnect all lamps by pressing the release tabs
on connectors and gently pulling apart Fig. 8 on
page 14.
4. Remove the spring clip Fig. 9 on page 14.
Carefully lift the lamp assembly, including lam
p
holder from the quartz tube Fig. 10 on page 14.
Do not pull excessively on the lamp wires.
5. Carefully remove new lamp assembly from box.
Insert lamp(s) into lamp holder. lamp(s) must b
e
aligned and seated securely in the lamp holder. Rol
l
the black o-ring(s) up onto the ceramic end of lam
p
from position A to B, Fig. 18, Fig. 19. Gently inser
t
lamps into the lower lamp retainer Fig. 17 and lower
lamp assembly into unit.
6. Re-install the spring clip and re-attach the lamp
connector(s) to the ballast. Note: The lamp
connector(s) can only be installed one way.
7. Discard lamp(s) appropriately. Visit
www.
lamprecycle.org
for instructions on disposal.