Ultratec Round Floor Pocket Скачать руководство пользователя страница 7

If your floor pocket is not raising or lowering;

Check air pressure:

 Is air getting to the solenoid valve?

Check that the air line is connected to a suitable air source at the required pressure.

Speed control valve: 

Are the speed control valves allowing air to pass through?

Try adjusting the speed control valve, for the direction that the unit is not responding to.

Power to solenoid:

 Is power getting to the solenoid?

Check that unit is connected to a suitable power source and that power is present when trying to raise 
Floor Pocket and removed when trying to lower the Floor Pocket lid.

Freezing:

 Use dry air as moisture can freeze and impair valve or cylinder action. 

Bent cylinder shaft:

 Stepping on lid can bend cylinder shaft.

Check that cylinder shaft is not bent. Replace the cylinder if it is bent.

One complete cycle (in & out)of the piston would use 4.2 cubic inches of volume at the 
recommended pressure of 30-100 psi. The compressed gas does not have to be air, you 
can use nitrogen or CO2 gas. CO2 is liquid in the tank so you can get a large volume from 
a small tank and regulator. A pressure regulator to drop the pressure is required. The 
number of cycles would depend on the volume of your tank. We offer a regulator and hose 
accessory to facilitate this. (see below).

CXP-1968    CO2 Regulator with 5 foot hose & High flow quick disconnect

.

 

This unit is used to supply regulated CO2 gas to run an assortment of peripheral devices 
that require a source of compressed gas. It may be used to run a floor pocket on an 
ECLIPSE system. Shown here on a 5 pound CO2 tank, (

tank is not included.)

Compressed Gas Usage

6

www.ultratecfx.com

Troubleshooting

Exterior

The casing of the Floor Pocket is stainless steel with a powder paint coating. To clean simply 
disconnect power source and wash with mild soap and warm water

Maintenance

Содержание Round Floor Pocket

Страница 1: ...Round Floor Pocket v 062020 Operators Manual ...

Страница 2: ... where you want it It has been designed to operate in conjunction with the ECLIPSE Low Fog Generator and designed to be flush mounted into the stage floor The Round Floor Pocket is pneumatically powered and electrically controlled Features Ÿ Powder Coated All Stainless Steel Chassis Ÿ Pneumatically Operated Electronically Controlled Ÿ DMX Control Available Ÿ Open Close Speed Adjustable Ÿ Mounts Fl...

Страница 3: ...ised by suitably trained and authorized personnel 2 Do not modify the machine or use a machine which has been damaged in any way 3 Allow sufficient air circulation around the machine at all times 4 Protect the machine from direct weather effects and wet locations 5 Only use fluids manufactured by Ultratec Special Effects 6 Do not continue to produce fog when visibility is reduced to 20 50cm or bel...

Страница 4: ...E REQUIRED 30 TO 100 PSI AIR HOSE 1 4 Poly Hose 60 long AIR CONNECTOR 1 4 Push lock style with 1 4 NPT termination Included in packaging Metal Mounting Ring 4 1 1 2 Screws REGULATORY COMPLIANCE This product has been certified to CSA UL Standards by QPS Canada Inc or CE depending on market Technical Specifications Technical Drawings 3 www ultratecfx com ...

Страница 5: ...ter if used See later in this manual 5 Place the metal ring onto the floor pocket aligning the mounting holes 6 Screw the ring and floor pocket to the floor using the supplied screws 7 Hook up power using the grey PowerCon Connector from the floor pocket and connecting to a controllable source DMX control can be obtained by using a DMX relay control like the CLF 2944 DMX Interface 110 Volt or CLF ...

Страница 6: ...adjustment screws located on the non rotating cylinder 2 flow adjustment screws The Directional Diverter may be removed if 360 degree output from the floor pocket is desired This is done by removing the 2 nuts under the floor pocket lid that hold the diverter in place Ideally this should be done before installation Operation Photo of Floor Pocket As Seen From Below 5 Floor Pocket Directional Diver...

Страница 7: ...plete cycle in out of the piston would use 4 2 cubic inches of volume at the recommended pressure of 30 100 psi The compressed gas does not have to be air you can use nitrogen or CO2 gas CO2 is liquid in the tank so you can get a large volume from a small tank and regulator A pressure regulator to drop the pressure is required The number of cycles would depend on the volume of your tank We offer a...

Страница 8: ...f the repair Ultratec Special Effects will return the unit via the most economical means available Should you require the item express returned the user dealer is responsible for indicating this request and for any difference in freight cost Warranty will be voided and customer will lose all rights guaranteed by the warranty if any of the following are observed occur If any non Ultratec Special Ef...

Страница 9: ... Effects GmbH Dieselstrasse 30 40 60314 Frankfurt am Main Germany Direct 49 69 87 000 1850 Fax 49 69 87 000 1899 Canadian Shipping Address For All Canadian Repairs Ultratec Special Effects 1960 Blue Heron Drive London Ontario N6H 5L9 USA Shipping Address For All USA Repairs Ultratec Special Effects 640 Gadson Street Groveland Florida 34736 Contact Us 8 www ultratecfx com ...

Отзывы: