background image

FCC INFORMATION

Your Intele–Modem complies with Part
68 of the Federal Communications
Commission (FCC) Rules. The label on
the bottom of your Intele–Modem
presents the following required
information. If the telephone company
requests this information, you must
provide it.

FCC Registration Number:
D8K7IB–10458–MD–E

Ringer Equivalence Number (REN):
0.4B

Jack: USOC RJ11W

Use a telephone company registered
jack to connect your Intele–Modem to
the telephone lines. Use registered jack
type USOC RJ11C. This jack is a
modular outlet that you can order from
your local telephone company or
telephone supply store. 

FCC rules do not permit you to connect
your Intele–Modem to a pay telephone.
Connection to party lines is subject to
state regulations.

Use the Ringer Equivalence Number
(REN) listed above to determine how
many direct connect devices you can
connect to your telephone line. When
you add up the REN numbers of all the
devices plugged into your phone line,
including telephones, modems, and
direct connect TTYs, the sum of the
RENs should not be more than five.
(This is for most areas of the country—
contact your local telephone company
to determine the exact maximum REN
for your local area.) If you plug too
many devices into your phone line,
some of them may fail to ring when
someone calls you.

The telephone company may make
changes in its facilities, equipment,
operations, or procedures that could
affect the proper functioning of your
Intele–Modem. If this happens, they

will notify you in advance to give you
the opportunity to maintain
uninterrupted service. If your
Intele–Modem causes harm to the
telephone network, your telephone
company has the right to discontinue
your service temporarily. If possible,
they will notify you in advance. But if
advance notice is not practical, they
will notify you as soon as possible. You
will have the opportunity to correct the
situation, and you will be informed of
your right to file a complaint with the
FCC.

Your Intele–Modem generates and uses
radio frequency energy, and may cause
radio or television interference. Your
Intele–Modem complies with the
regulations for a Class B computing
device as specified in Subpart J of Part
15 of the FCC Rules. These rules are
designed to minimize radio frequency
interference in residential
installations. 

Use your Intele–Modem in strict
adherence with these instructions.

There is no guarantee that radio
frequency interference will not occur
during use. You can determine if your
Intele–Modem causes interference to
radio or television reception by
disconnecting and reconnecting it
while your radio or television is on.

If radio frequency interference occurs,
try to correct it by:

re-orienting the radio or television
receiving antenna;

moving your Intele–Modem away from
the receiving antenna; or

moving your Intele–Modem away from
the radio or television.

If necessary, consult an experienced
radio/television technician for
additional suggestions.

Содержание INTELE-MODEM

Страница 1: ...HOW TO USE YOUR INTELE MODEM 305 008800...

Страница 2: ...3008 Email service ultratec com www ultratec com First Edition October 1998 First Printing 1989 1998 Ultratec Inc is a registered trademark of Ultratec Inc Intele Modem and Intele Menu are trademarks...

Страница 3: ...etting Up Auto Answer 8 The Intele Menu Command Set 9 How to use the commands 9 What each command does 10 Telephone functions 10 Communication settings 11 Message functions 12 Auto Answer functions 13...

Страница 4: ...II CONTENTS...

Страница 5: ...tele Modem can use either the American standard of 45 baud or 50 baud The Intele Modem is Hayes compatible This means you can use Hayes commands also called AT commands to control your modem The Intel...

Страница 6: ...on 7 Press the Escape Key and type H to hang up How to answer a call 1 Set up your Intele Modem and computer and turn them on 2 Load your communications software 3 Press the Escape Key and the Spaceba...

Страница 7: ...ere are many different programs that will work Any program that provides for terminal emulation will do If in doubt ask your computer store or microcomputer user group for the software that works best...

Страница 8: ...ith Baudot code see page 14 Talking to the modem vs another computer or TTY______________ No matter which command set you use your Intele Modem operates in two modes Issuing commands is done in comman...

Страница 9: ...first See the Problems and Solutions section on page 21 for more information Step by step instructions_____________________________________ Modem settings When you follow these instructions you will...

Страница 10: ...messages in ASCII code If you re using Baudot code the SIG Signal light will also flash If you don t see what you re typing on the computer monitor change your duplex setting to half duplex Type the E...

Страница 11: ...ect light goes on and you read CONNECT on your monitor your Intele Modem has connected with a computer and is communicating in ASCII code You won t know for sure if you ve connected in Baudot code unt...

Страница 12: ...u re finished You will return to the Command Line 6 Type the Z Command You ll see the message Auto Answer on Press any key to abort When it answers the phone the Intele Modem will respond in 300 baud...

Страница 13: ...if you type you ll see the help menu The help menu is shown below Each letter or number listed on the help menu is a command which will change how the modem operates Don t worry you won t have to use...

Страница 14: ...Intele Modem will dial using either tone or pulse dialing depending on how the T command is set You can include parentheses and a dash in the number although they re not necessary Type a comma within...

Страница 15: ...Answer The default is Answer mode This command has two settings Origi nate and Answer It applies only to ASCII code communication It has no effect when using Baudot code Originate When the modem is u...

Страница 16: ...Message Functions __________________________________________ Message Functions allow you to type and store a message and send it later Note that there are two separate message areas The Message Functi...

Страница 17: ...allows you to enter a new Auto Answer message Typing N for No returns you to the Command Line and preserves the old message You ll see the following prompt when you answer yes Enter new answer message...

Страница 18: ...modem dials If the phone rings you ll see the message RINGING on your screen If the phone is busy you ll see the message BUSY on the screen 6 When someone answers your Intele Modem will listen for an...

Страница 19: ...T TTY on your monitor when the SIGNAL light goes on your Intele Modem has connected with a TTY and is communicating in Baudot code 5 Once you establish a connection you can go ahead with your conversa...

Страница 20: ...or string them together after a single AT ATB1F0D5551212 Enter You can type commands in a solid string of characters as shown above or you can put spaces between command characters to make them easie...

Страница 21: ...de 110 baud Use this setting for making calls to 110 baud ASCII TTYs D Dial telephone Type AT followed by D to dial a phone number from your computer keyboard Press the Enter Key to dial For example A...

Страница 22: ...S registers For example the command ATS1 asks the modem for the number of times the phone has rung S0 number of rings The default is S0 0 When the modem is in answer mode the S0 register tells it how...

Страница 23: ...rier loss and hang up The default is S10 14 In ASCII mode the modem automatically hangs up when it loses the carrier tone This register allows the carrier to disappear for a short period of time perha...

Страница 24: ...ading OK you ll read 0 V1 Your modem uses word responses such as OK X Response message list The default is X1 You can select the number of response messages listed above that you want your Intele Mode...

Страница 25: ...wo speeds 110 baud and 300 baud Each time you type the command it switches from one to the other Press the Escape Key and at the Command Line type 3 Press the Return Key to go back on line You can see...

Страница 26: ...2 TXD 3 RXD 4 DTR 5 GND 8 CTS Audio Monitor Internal speaker with volume control Compatibility ASCII Bell 103 110 300 bps asynchronous TTY Baudot 45 5 or 50 baud 1400 1800 Hz Dialing Tone or pulse An...

Страница 27: ...end it to National Service Center Ultratec Inc 5901 Research Park Blvd Madison WI 53719 Telephone 608 238 5400 V TTY Email service ultratec com Since Ultratec cannot be responsible for any damage to y...

Страница 28: ...II and Baudot codes organize bits differently Each letter number or symbol in ASCII code is described by 7 bits of information In Baudot code each character is described by 5 bits Duplex full or half...

Страница 29: ...LSE O Originate Answer ANSWER F Full Half Duplex HALF MESSAGE FUNCTIONS E Echo ON OFF ON I Hi sensitivity OFF N Enter new message L List message 0 chars S Send message C Current communication settings...

Страница 30: ...4 4 53 35 5 5 54 36 6 6 55 37 7 7 56 38 8 8 57 39 9 9 58 3A 59 3B 60 3C 61 3D 62 3E 63 3F 64 40 65 41 A A 66 42 B B 67 43 C C 68 44 D D 69 45 E E 70 46 F F 71 47 G G 72 48 H H 73 49 I I 74 4A J J 75 4...

Страница 31: ...tions or procedures that could affect the proper functioning of your Intele Modem If this happens they will notify you in advance to give you the opportunity to maintain uninterrupted service If your...

Страница 32: ......

Отзывы: