background image

PD1+ combi 

The 

PD1+ combi 

operates in a similar manner to the 

PD1 combi.

 

The unit is turned on by pressing the on/off control 

(B)

, the system 

micro-controller monitors the detected signal and turns the unit off 
when no signal has been detected for approximately 2 minutes. 
The LCD displays battery condition and fetal heart rate 

(F)

. A 

battery icon 

(C) 

is displayed when the battery requires changing. 

The fetal pulse icon 

(G) 

flashes at approximately the same 

rate as the detected fetal heart. 
Serial RS232 connection can be made by attaching the optional 
serial link cable to socket 

(H) 

on the side of the unit - contact 

supplier for further details. 

(A) 

(G) 

(B) 

(D) 

(H) 

(F) 

(C) 

 

 

 
 

Transducer colour coding 

 

Connector ring colour 

 

2MHz       

Red

 

3MHz       

Orange

 

5MHz       

Green

 

8MHz       

Grey

 

Содержание PD1 combi

Страница 1: ...PD1 combi PD1 combi operating instructions ultrasound technologies...

Страница 2: ......

Страница 3: ...l fetal heart rate detection and rate display on an LCD display and an RS232 data port for the transfer of data to a PC to review the fetal heart rate traces The instrument is supplied complete with t...

Страница 4: ...ocated on the front of the PD1 combi unit B The PD1 combi will stay on for approximately 5 minutes or until the on off switch is pressed again With the unit on the volume can be adjusted by the rotary...

Страница 5: ...he LCD displays battery condition and fetal heart rate F A battery icon C is displayed when the battery requires changing The fetal pulse icon G flashes at approximately the same rate as the detected...

Страница 6: ...s Later on in pregnancy the best signals are generally found higher up the abdomen Avoid sliding the transducer over the abdomen as this results in an increase in the background noise and makes it mor...

Страница 7: ...cuff and sphygmomanometer to indicate the location and extent of arterial occlusion in the form of ankle brachial pressure index and segmental pressures Due to the variation of leg blood pressure over...

Страница 8: ...ator 50 210 bpm Unit Controls Keys 1 key for unit on off 1 key for unit on off Controls Rotary Volume Rotary Volume Indicators Yellow LED for battery low LCD Display with icon for battery low and puls...

Страница 9: ...no audio signal is heard in the loudspeaker consult your supplier When contacting your supplier with a problem please have available the instrument type and serial number The serial number can be fou...