3.4. Operating the Equipment 
 

1. 

Getting Started

 

– Locate the unit on a solid and level surface. 

 

2. 

Filling the Unit

 

– Check to be sure the drain valve is tightly closed. Fill the tank up 

to the recommended working level with high quality water (A good rule of thumb is 
to fill the tank to ¾ full). To protect against overflow, allow space in the tank for the 
water displacement of the items that are to be placed in the tank.  If tap water is not 
of good quality, it is recommended that filtered water is used to allow the detergent 
to perform at its highest level.  
 

3. 

Set  Heater  temperature

 

–  For  most  industrial  applications,  140

F  is  the 

recommended fluid temperature. Some applications or detergents will require other 
temperatures and may be as low as 90

F. Consult your sales representative if you 

do not know what temperature to set the unit to. 

 
4. 

Adding  Chemicals

 

–  Use  the  mixture  rate  recommended  by  the  detergent 

manufacturer.  After  cleaning  one  or  two  items,  you  may  choose  to  increase  the 
chemical ratio. The amount of chemical will be based on the condition of the water 
being  used  and  how  much  contamination  is  to  be  removed.    Detergents  that  are 
used  in  this  ultrasonic  cleaning  system  must  be  compatible  with  304  and  316L 
stainless  steel. 

You  will  void  the  warranty  if  chemical  attack  to  the  stainless 

steel occurs. 

 

5. 

Tank Power On

 

– On the tank, turn 

ON

 the main power switch.

 

 

6. 

Ultrasonic  Power  On

 

–  On  the  digital  controller,  press  the  “

F

”  key  to  turn  on the 

internal generator. (

DO NOT

 turn on the ultrasonics without having liquid in the tank, 

doing so will damage the ultrasonic transducers). Rotate the "

Power Intensity

" dial 

clockwise (ultrasonic sound will increase).  

 

 

7. 

Operating  the  Digital  Controller

 

–  Your  system  comes  equipped  with  a  digital 

controller for managing the temperature and timers. The temperature of the system 
will automatically be maintained based upon the set temperature. Setting the timer 
will allow for precise control of the length of the ultrasonic cleaning cycle. Below is 
additional information regarding the operation of this controller.  

Содержание SE Series

Страница 1: ...1 Publication Number UPC211216 003 1 Benchtop SE Series System Manual Ultrasonic Power Corporation 239 E Stephenson Street Freeport IL 61032 U S A Phone 815 235 6020 1 800 575 0168 Fax 815 232 2150 Em...

Страница 2: ...take some time to familiarize yourself with this manual and all aspects of the system configuration prior to start up We know that your Ultrasonic Power Corporation cleaning system will serve you for...

Страница 3: ...nings 4 1 Specifications 8 2 Principles of Operation 11 3 Operating Instructions 12 4 Inspection and Maintenance 17 5 Troubleshooting 19 6 Component Repair and Replacement 20 7 Diagrams and Drawings 2...

Страница 4: ...rsonal injury or death Warning The WARNING symbol means that failure to follow this safety statement MIGHT result in personal injury or death Caution The WARNING symbol means that failure to follow th...

Страница 5: ...n and damage delicate components CAUTION Incorrect voltage can damage the generator Do not operate the equipment unless the correct voltage is available Contact the proper authority about necessary ch...

Страница 6: ...Do not carry on conversation or permit yourself to be distracted in any manner while servicing live equipment Never service live equipment unless someone else is in the same room with you Never turn...

Страница 7: ...cted by splashing water and debris to a rating of IP 23 This system contains one power cord that is required to be attached to a properly rated three wire fusible disconnect with a grounding connectio...

Страница 8: ...Heater Power 500 Watts Estimated Heat Up Time 1 4 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight Subject to change Not the same as sh...

Страница 9: ...ower 500 Watts Estimated Heat Up Time 2 5 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight Subject to change Not the same as shipping w...

Страница 10: ...Power 1000 Watts Estimated Heat Up Time 2 7 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight Subject to change Not the same as shipping...

Страница 11: ...ic Power Corporation utilizes our 5300 5400 series generators 2 Vibra bar transducer technology to convert electrical energy received from the generator into mechanical energy a Transducers fall into...

Страница 12: ...ble into the appropriate voltage outlet Using incorrect voltage will not allow the cleaner to operate properly and may damage the system 3 3 Generator Control Knobs 1 Power Intensity This knob control...

Страница 13: ...ded by the detergent manufacturer After cleaning one or two items you may choose to increase the chemical ratio The amount of chemical will be based on the condition of the water being used and how mu...

Страница 14: ...stop the timer and cause it to reset While the timer is running the ultrasonic generator will be turned on The default units for the timer is Hours Minutes 3 t1 Red Time Remaining Green Use the arrow...

Страница 15: ...acts the part s surface It may be necessary to rotate the part while submersed to allow air to escape Some initial testing will help determine the proper settings for the optimum time and temperature...

Страница 16: ...decrease and turn OFF the main power switch 3 4 Filter Operation Optional Accessory 1 Turn ON the main power switch 2 Press the filter system button to turn it ON Allow the filter system to clean the...

Страница 17: ...c If applicable make sure the castors are locked in place to prevent movement of system during operation d If applicable be sure all side panels are in place on the system NOTE All side panels must b...

Страница 18: ...LL RECEPTACLE BEFORE PERFORMING ANY PREVENTATIVE MAINTENANCE FUNCTIONS WITHIN ANY COMPARTMENTS ELECTRICAL SHOCK CAN CAUSE SERIOUS INJURY Recommended maintenance cycle is 3 months 1 Wash tank interior...

Страница 19: ...cord b Building power supply c Unit s fuses d Loose disconnected wires e Switches PROBLEM ITEMS TO CHECK 2 The ultrasonics do not work a Building power supply b Unit s fuses c Loose disconnected wires...

Страница 20: ...OLLOWING PRECAUTIONS WHEN WORKING ON THE EQUIPMENT 1 NEVER REACH ACROSS A SYSTEM WHICH HAS NOT BEEN TURNED OFF THE PLUG PULLED AND THE HIGH VOLTAGE CAPACITORS DISCHARGED 2 WHEN SERVICING LIVE ELECTRON...

Страница 21: ...Check for loose connection of wires 4 Check supplied power for correct voltage specifications 5 Test generator by turning the system on 6 If generator does not work contact Ultrasonic Power Corporatio...

Страница 22: ...em tank 4 Check for loose or damaged wires If damage is visible contact Ultrasonic Power Corporation service department for repair or replacement 6 5 PUMP FILTER PRE STRAINER OPTIONAL ACCESSORY 1 Remo...

Страница 23: ...ransparent pre strainer and remove contaminants from mesh screen Return screen to pre strainer Ensure washer is seated properly Hand tighten pre strainer back in place Return pre strainer valve to ON...

Страница 24: ...Property of Ultrasonic Power Corporation 2021 Publication Number UPC211216 003 24 7 Diagrams and Drawings 7 1 BT 40SE Drawings and Schematics BT 40SE Standard Drawing...

Страница 25: ...Property of Ultrasonic Power Corporation 2021 Publication Number UPC211216 003 25 BT 40SE Standard Schematic...

Страница 26: ...Property of Ultrasonic Power Corporation 2021 Publication Number UPC211216 003 26 7 2 BT 60SE Drawings and Schematics BT 60SE Standard Drawing...

Страница 27: ...Property of Ultrasonic Power Corporation 2021 Publication Number UPC211216 003 27 BT 60SE Standard Schematic...

Страница 28: ...Property of Ultrasonic Power Corporation 2021 Publication Number UPC211216 003 28 7 3 BT 130SE Drawings and Schematics BT 130SE Standard Drawing...

Страница 29: ...Property of Ultrasonic Power Corporation 2021 Publication Number UPC211216 003 29 BT 130SE Standard Schematic...

Страница 30: ...ty or to meet any liability which may arise by reason of any defect in such Third Party Product UPC HEREBY DISCLAIMS ANY WARRANTY EXPRESSED OR IMPLIED FOR FITNESS OF PARTICULAR PURPOSE OR OTHERWISE FO...

Страница 31: ...unty of Winnebago State of Illinois c This Warranty constitutes the entire understanding between the parties with respect to the subject matter discussed herein and supersedes any prior discussions ne...

Страница 32: ...C policy for the repair of equipment Payment confirmation pursuant to the quote provided by UPC must be received prior to any repair being made The initial diagnostic fee charged covers all testing di...

Страница 33: ...e of the shipping package Packages without RMA on the outside will be refused Cleaning Fee May be Assessed Important UPC does not have environmental permits or the facilities to address cleaning mater...

Страница 34: ...ensure that the power has been disconnected and that the liquid has been entirely drained from the system prior to movement Wipe down the system to remove all excess liquid Wrap up the power cable to...

Страница 35: ...for Immersible Transducers Comments Warranty Repair 0 00 UPC Warranty Applies Test Evaluation Fee 150 00 Waived with warranty replacement due to defect NON Warranty Quote Expired warranty equipment m...

Страница 36: ...onic Power Corporation 2016 Publication Number UPC160421 003 36 From RMA Ship To Ultrasonic Power Corporation 239 East Stephenson Street Freeport IL 61032 Attention RMA Coordinator cut here FRAGILE EL...

Страница 37: ...filter 50 70 734 10 20 Micron filter 50 70 584 T strainer 50 70 835 O ring for filter housing 50 40 139 20 Filter Housing 50 70 816 10 Filter Housing 50 70 769 Gauge for Filter housing 50 70 770 Pump...

Отзывы: