background image

Property of Ultrasonic Power Corporation - 

© 2017

 

 

 

 

 

 

 

 

 

Publication #070119

 

 

 

 

 

 

 

 

 

28

 

 

14. Return of Equipment Policy

 

 

Replacement/Repair Policy and Pricing Schedule 

It is the intention of Ultrasonic Power Corporation (UPC) to deliver fair, accurate, cost-effective and timely service 
associated with warranty and non-warranty product assistance to Original Equipment Manufacturers (OEM), End-
user and Reseller Customers within the guidelines of this Policy.  All warranty repair costs that fall within the scope 
of a UPC Warranty Policy will be covered, in full, according to the applicable UPC Warranty Policy. All non-
warranty and customer damage repairs will be quoted according to inspection criteria and pricing schedule for the 
associated Product.  

Visit our website before returning any product. 

www.upcorp.com

  

A Return Material Authorization (RMA) number must be assigned prior to returning any product.  
Contact RMA Coordinator at +1 815 235 6020 :  Monday – Friday 7:00 AM to 5:00 PM Central Time (UST -6)   

Warranty  

Repairs will be covered in accordance with the applicable UPC Warranty Policy. All warranty repairs are subject to 
an initial inspection and approval by an authorized UPC repair representative to determine if the requested repairs 
are covered by an applicable UPC Warranty Policy. If a repair is NOT covered under warranty, UPC will issue a 
quote for the cost of the repairs needed and will provide a stated reason for the non-warranty coverage 
determination. As indicated in each UPC Warranty Policy, all warranties are void if the warranty “tamper seal” is 
broken or Products or Accessories has been modified and/or repaired by anyone other than a UPC repair 
representative.   

Non-Warranty and Customer Damage 

Work by UPC will be performed in accordance with the UPC policy for the repair of equipment.  Payment 
confirmation pursuant to the quote provided by UPC must be received prior to any repair being made. The initial 
diagnostic fee charged covers all testing, diagnosis, parts, and labor to determine the cause of the defect and the 
repair necessary to restore full functionality of the returned equipment. Returned equipment that is determined 
“beyond repair” due to non-UPC causes (customer, accident, weather, etc.) will not be repaired.   There will be no 
refund of the diagnostic fee for equipment determined to be beyond repair.   
 

Property Loss and Beyond Repair 

A determination will be made upon receipt of product to determine whether or not the product can be repaired. In 
the event a product is determined to be “beyond repair”, UPC will notify the customer with a stated reason for the 
“beyond repair” determination. UPC reserves the right, at its sole discretion, to offer replacement equipment, parts, 
etc., in exchange for any product that is deemed “beyond repair”.  Pricing will be determined based on the repair 
pricing schedule; 

forfeiture to UPC of the original product is required if replacement is offered and agreed to 

by the customer.  
 

Testing/Evaluation Fees 

Diagnostic Fees will apply to all products returned to UPC for repair or replacement. A fee is assessed to cover 
expense of testing, inspecting, evaluating and the costs for non-UPC or non-product related issues.  If a Warranty 
Replacement or Warranty Repair is required by the applicable UPC Warranty Policy, this diagnostic fee is waived. 
If a non-warranty replacement or non-warranty repair is required, the diagnostic fee is accounted for in the Pricing 
Schedule.  

 
Shipping Expenses/Abandoned Product/Failure to Authorize Repair in Timely Manner 

Shipping expenses are the responsibility of the customer. UPC recommends a shipping method which provides for 
tracking of returned product and also includes insurance against shipping damage and/or property loss. UPC will not 

Содержание BT H Series

Страница 1: ...017 Publication 170119 jsw 1 BT H Series Cleaning Systems Basic and Advanced Ultrasonic Power Corporation 239 E Stephenson Street Freeport IL 61032 U S A Phone 815 235 6020 1 800 575 0168 Fax 815 232...

Страница 2: ...ime to familiarize yourself with this manual and all aspects of the system configuration prior to start up We know that your Ultrasonic Power Corporation cleaning system will serve you for years to co...

Страница 3: ...inciples of Operation 11 4 Description of Components 12 5 Preparation of Use Getting Started 13 6 Operating Instructions 14 7 Accessories 15 8 Techniques for Optimizing Cleaning Results 17 9 Maintenan...

Страница 4: ...signal word is to be limited to the most extreme stuations Warning Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Caution Indicates an imminen...

Страница 5: ...S TOXIC FUMES CAUTION Never use ultrasonic cleaning console as a sink Under no circumstances should waste water be poured into it as the water could overflow the drain and damage delicate components C...

Страница 6: ...pable of handling twice the rated current The wires are colored as follows black hot ungrounded white return grounded green yellow protective earth The system also contains one drain valve for tank co...

Страница 7: ...nts Volts 120 120 120 120 120 System Electrical Supply Requirements Amps 5 0 5 0 5 0 5 0 8 3 Generator Electrical Supply Requirements Volts 120 120 120 120 120 Generator Electrical Supply Requirements...

Страница 8: ...Volts 120 120 120 120 120 System Electrical Supply Requirements Amps 8 3 8 3 8 3 12 5 16 7 Generator Electrical Supply Requirements Volts 120 120 120 120 120 Generator Electrical Supply Requirements A...

Страница 9: ...rements Amps 8 3 16 7 Generator Electrical Supply Requirements Volts 240 120 Generator Electrical Supply Requirements Amps 8 0 21 2 Ultrasonic Power Watts 1500 2000 Frequency of 5300 Series Generator...

Страница 10: ...enchtop H Series Heater Fuse BT 1206 250 6 Fast BT 2406 250 6 Fast BT 3606 250 6 Fast BT 60H 250 6 Fast BT 130H 250 10 Fast BT 2412 250 10 Fast BT 90H 250 10 Fast BT 6006 250 10 Fast BT 3612 250 15 Fa...

Страница 11: ...stals The vibrations are transferred from the piezoelectric converters to the high grade stainless steel tank via the VIBRA Bar bonded directly to the tank This vibration is what powers the ultrasonic...

Страница 12: ...e patented 5300 series ultrasonic generator The generator supplies the specified signal to the transducers The high efficiency of the generator ensures the maximum cleaning power delivered to the tank...

Страница 13: ...st and water that gets into the generator may cause electrical damage to the system Ensure maximum airflow to keep the internal components operating at peak performance On the H series systems connect...

Страница 14: ...ease After each fill up of the tank allow the ultrasonic run for a minimum of 10 minutes at 80 power to allow the ultrasonic Degas the liquid removed excess air molecules thus increasing efficiency If...

Страница 15: ...heaters Turn the Main Power to the OFF position Wipe down the machine with a towel to inhibit rusting 7 Accessories Digital Timer Unit Option Provides a timer that automatically turns off the ultraso...

Страница 16: ...nding the useable life of the liquid Basket Option The basket is made to fit each particular system In assists in placing items in the tank without placing your hands in the liquid It also assists in...

Страница 17: ...to ten minutes since very few parts are sufficiently clean within a few seconds Pre cleaning may be required to remove gross contamination or to chemically prepare the parts for a final clean Some app...

Страница 18: ...edure for ultrasonic cleaning is generally as follows Put parts in basket and place basket through three or four process steps ultrasonic wash spray rinse optional immersion rinse dry Some parts loade...

Страница 19: ...However there is what is known as the large tank phenomenon which indicates that tanks over 50 gallons usually require only about 20 watts per gallon The only explanation available is a point of dimi...

Страница 20: ...that is to be used in the ultrasonic cleaning system Test the cleaning capabilities of the system after each change in liquid dilution of chemical ratio adding chemical changing of liquid Locate the u...

Страница 21: ...Blow out the internal parts of the generator with an air hose Careful use of air pressure may be used to remove dirt from critical areas Periodically check the generator air intake for buildup of dus...

Страница 22: ...nob clockwise if applicable 5 If the above did not solve the problem Call the Ultrasonic Power Corporation customer service department for assistance The liquid does not heat up 1 Ensure the tank powe...

Страница 23: ...Property of Ultrasonic Power Corporation 2017 Publication 170119 jsw 23 11 Diagrams and Drawings BT H Model Tank Wiring Diagram...

Страница 24: ...Property of Ultrasonic Power Corporation 2017 Publication 170119 jsw 24...

Страница 25: ...Property of Ultrasonic Power Corporation 2017 Publication 170119 jsw 25 12 Component List Tank Generator Pump and Filter H Models Pump and Filter Stand...

Страница 26: ...o meet any liability which may arise by reason of any defect in such Third Party Product UPC HEREBY DISCLAIMS ANY WARRANTY EXPRESSED OR IMPLIED FOR FITNESS OF PARTICULAR PURPOSE OR OTHERWISE FOR ALL T...

Страница 27: ...Winnebago State of Illinois c This Warranty constitutes the entire understanding between the parties with respect to the subject matter discussed herein and supersedes any prior discussions negotiati...

Страница 28: ...y for the repair of equipment Payment confirmation pursuant to the quote provided by UPC must be received prior to any repair being made The initial diagnostic fee charged covers all testing diagnosis...

Страница 29: ...e shipping package Packages without RMA on the outside will be refused Cleaning Fee May be Assessed Important UPC does not have environmental permits or the facilities to address cleaning materials co...

Страница 30: ...sible Transducers Comments Warranty Repair 0 00 UPC Warranty Applies Test Evaluation Fee 150 00 Waived with warranty replacement due to defect NON Warranty Quote Expired warranty equipment malfunction...

Страница 31: ...of Ultrasonic Power Corporation 2017 Publication 070119 31 RMA Ship To Ultrasonic Power Corporation 239 East Stephenson Street Freeport IL 61032 Attention RMA Coordinator cut here FRAGILE ELECTRONIC E...

Страница 32: ...et heater 50 31 040 Analog thermostat 50 31 021 Digital Thermostat Controller TCS 4010 50 31 046 Digital Thermostat Controller TCS 4020 For BT 330H 50 31 027 Lit amber rocker switch 50 06 050 Fuse 6A...

Страница 33: ...Property of Ultrasonic Power Corporation 2017 Publication 070119 33 Please contact your Ultrasonic Power Corporation representative with any question regarding your Ultrasonic cleaning system...

Отзывы: