background image

READ IT

 

OR

 

WATCH IT

Read instructions or watch easy-to-follow video. 

Scan QR code or visit https://byjasco.com/40955i

40955

24-HOUR IN-WALL 

DIGITAL TIMER

AFTER INSTALLATION

Use a pencil or toothpick to press and release the 

reset button behind the door between the 

ON TIME 

and the 

OFF TIME

 buttons.

SET THE TIME

Use up (   ) and down (   ) arrows to select time.
Take note of the AM/PM setting.

CHOOSE YOUR PROGRAM

Note: 

If no button is pushed for 5 seconds, the 

timer returns to clock mode indicated by an arrow 

under “CLOCK.”
There are three preset times that run individually or 

simultaneously. Choose from the following:

COUNTDOWN
EVENING (5PM - 12AM)
MORNING (5AM – 8AM)

When a schedule is chosen, the amber LED 

indicator light will turn on. You may run multiple 

schedules.

CHOOSE YOUR CUSTOM ON/OFF TIMES

Press and release 

ON TIME

, then use up (   ) and 

down (   ) arrows to set on time. Press and release 

OFF TIME

, then use up (   ) and down (   ) arrows 

to set off time. If the amber LED is off, the program 

will not operate. Repeat for the other 

ON TIME 

or 

OFF TIME

 buttons. All programmed times will run 

simultaneously in a 24-hour day.

ADDITIONAL FEATURES

COUNTDOWN

 - This feature turns the light on for a 

set period and turns it off when time expires. Press 

and release 

COUNTDOWN

, then use up (   ) and 

down (   ) arrows to set from 1 minute to 24 hours. 

Once you reach your desired time setting, simply 

walk away and the timer begins counting down. 

Your last time setting will be remembered the next 

time you use the 

COUNTDOWN

 feature.

MANUAL/OVERRIDE

 - Press and release 

ON/OFF

 

button or the closed door to manually control lighting.

Note: 

When daylight saving time occurs, use up       

(   ) and down (   ) arrows to adjust the time by 

one hour.

AM

CLOCK        SET      COUNTDOWN

ON  / OFF

COUNTDOWN

MORNING 5-8

ON TIME

OFF TIME

OFF TIME

ON TIME

EVENING 5-12

AM

CLOCK        SET      COUNTDOWN

ON  / OFF

COUNTDOWN

MORNING 5-8

ON TIME

OFF TIME

OFF TIME

ON TIME

EVENING 5-12

AM

CLOCK        SET      COUNTDOWN

ON  / OFF

COUNTDOWN

MORNING 5-8

ON TIME

OFF TIME

OFF TIME

ON TIME

EVENING 5-12

AM

CLOCK        SET      COUNTDOWN

ON  / OFF

MORNING 5-8

ON TIME

OFF TIME

OFF TIME

ON TIME

EVENING 5-12

COUNTDOWN

Supplier Declaration of Conformity | Model #: 40955 | Jasco Products Co.,                  

10 E. Memorial Rd., Oklahoma City, OK 73114, www.byjasco.com
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS 

standards. Operation is subject to the following two conditions: (1) this device may not 

cause harmful interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation.

FCC NOTE:

 The manufacturer is not responsible for any radio or TV interference  

caused by unauthorized modifications to this equipment. Such modifications could 

void the user’s authority to operate the equipment.

NOTE:

 This equipment has been tested and found to comply with the limits for a Class 

B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to 

provide reasonable protection against harmful interference in a residential installation. 

This equipment generates, uses and can radiate radio frequency energy, and if not 

installed and used in accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee interference will not occur 

in a particular installation. If this equipment does cause harmful interference to radio 

or television reception, which can be determined by turning the equipment off and 

on, the user is encouraged to try to correct the interference by one or more of the 

following measures:

— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from which the receiver  

is connected.

— Consult the dealer or an experienced radio/TV technician for help.

CAN ICES-3(B)/NMB-3(B)

120VAC 60Hz
15A General/Resistive
1200W Tungsten
1200VA Standard Ballast
1/2HP
5A or 600W Electronic Ballast/LED
Works with LED, CFL, incandescent and halogen bulbs.

FCC/IC - EN

SPECIFICATIONS

AM

CLOCK        SET      COUNTDOWN

ON  / OFF

COUNTDOWN

MORNING 5-8

ON TIME

OFF TIME

OFF TIME

ON TIME

EVENING 5-12

AM

CLOCK        SET      COUNTDOWN

ON  / OFF

MORNING 5-8

ON TIME

OFF TIME

OFF TIME

ON TIME

EVENING 5-12

COUNTDOWN

RESET 

BUTTON

MADE IN CHINA/HECHO EN CHINA
Distributed by Jasco Products Company LLC, 10 E. Memorial Rd., Oklahoma City, OK 73114.
This Jasco product comes with a 2-year limited warranty. Visit www.byjasco.com for     

warranty details.
Questions? Contact our U.S.-based Consumer Care at 1-800-654-8483 between 

7AM-8PM M-F, Central Time.
©JASCO 2020 | 40955 | 09/11/20 v2

RISK OF ELECTRICAL 

SHOCK

• SHUT OFF POWER AT FUSE 

BOX OR CIRCUIT BREAKER 

BEFORE INSTALLATION

• DO NOT USE IN WET 

LOCATIONS

• USE INDOORS ONLY

RISK OF FIRE

• DO NOT USE TO CONTROL 

APPLIANCES THAT CONTAIN 

HEATING ELEMENTS 

(COOKING APPLIANCES, 

HEATERS, IRONS, ETC.)

• DO NOT EXCEED 

ELECTRICAL RATINGS

• DO NOT USE TO CONTROL 

RECEPTACLES

• USE COPPER WIRE ONLY 

WITH THIS DEVICE

• TIGHTEN ALL 

CONNECTIONS TO 1-1.4 N-M 

(8.85 TO 12.39 LBF-IN.)

• FOR SUPPLY CONNECTIONS, 

USE 14AWG OR LARGER 

WIRE RATED AT LEAST 

75° C

• FOR GROUNDING LEAD, USE 

12AWG OR LARGER WIRE 

RATED AT LEAST 75° C

WARNING