9
3. Disassembly
a.)
To remove the head, rotate the locking ring
on the handle until the head becomes loose.
Pull the head straight away from the handle.
b.)
To remove the power or battery pack,
squeeze both tabs on the sides of the item, then
pull straight out.
LED HEAD
WAVELENGTH (nM)
EVIDENCE
GLASSES
BMT™
450 nM
99.5% Of All Evidence
Amber
UV
400 nM
Body Fluids, Bite Marks
Bruise Evidence
Amber
Red
Yellow
GREEN
525 nM
Trace Evidence
Fingerprints, Fibers
Amber
Red
YELLOW
590 nM
Fingerprints, Fibers
Altered Documents
Amber
Red
RED
630 nM
Fibers, Altered Documents
Amber
INFRARED (IR)
850 nM
Altered Documents, cleaning
solvents, fresh paint, and
explosive residues
Infrared detection cameras and
other devices
WHITE
Full Spectrum
400-750 nM
6500 kalvin
General crime scene search,
oblique lighting; hair, fiber &
fingerprints
None or Yellow forensic goggles
and filters
When mounting the Head Assembly to the UltraLite ALS®,
twist the Locking Ring only. DON’T TWIST THE HEAD!
Head
Locking Ring
OPERATOR’S MANUAL