CH0002 Operation Manual
Newark, New York | 315-332-7100 | Fax: 315-331-7800
©2011 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice
The information contained herein is for reference only and does not constitute a warranty of performance •
11 AUG 11
UBI-5133 Rev: D
Page 4 of 5
U
SE ONLY WITH
UBI-2590
(UBBL02,
UBBL10,
UBBL13)
L
ITHIUM
-I
ON
B
ATTERY
1. Before You Begin
1.1. The charger consists of three parts: a line cord, a power supply (PS2524), and a charge control
module that has a charge cable attached. Make certain the line cord is the proper type for your
application (i.e. the plug is correct for your wall outlet.)
1.2. The charger is designed for use between 0°C an d 45°C (32°F and 113°F.) Failure to operate
charger in this range will result in reduced battery capacity and/or ability of safety devices to
activate.
2. Function
2.1. The charger is designed to charge each section of any UBI-2590 battery independently. This
assures that the two sections of the battery are both fully charged and assists in maintaining
proper charge balance within the battery.
3. Connection Instructions
3.1. Connect the line cord to the power supply.
3.2. Connect the power supply to the charge control module.
3.3. The charge control module has a built-in mating connector that will connect to any of the UBI-
2590 batteries. Carefully orient the connector so that Pin 1 matches Pin 1 on the battery
connector. Press the connector firmly into the battery.
NOTE: Although the connector is keyed, failure to orient it properly can cause damage to battery
and/or charger.
3.4. The charger will automatically detect the presence of a connected battery and initiate the
charging sequence. This is identified by the blinking green lights on the charger.